FUMED SILICA FOR THE DIRECT DETERMINATION OF LEAD IN URINE BY DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRY

被引:10
作者
STAUBER, JL
FLORENCE, TM
机构
[1] CSIRO Centre for Advanced Analytical Chemistry, Division of Fuel Technology, Menai, NSW
关键词
Fumed silica; Lead; Urine;
D O I
10.1016/S0003-2670(00)83915-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of fumed silica for the direct determination of lead in urine by differential-pulse anodic stripping voltammetry was investigated. Fumed silica, added to urine prior to the nitrogen purge step, completely removed sorption interferences by urinary organic constituents. Values for lead in urine from eight unexposed individuals were 3 ± 2 μg l-1 or 3 ± 2 μg g-1 creatinine. This method is a fast, simple and effective means for the accurate determination of lead in undiluted urine without pretreatment. © 1990.
引用
收藏
页码:177 / 180
页数:4
相关论文
共 12 条
[1]   IRRADIATION TECHNIQUES FOR RELEASE OF BOUND HEAVY-METALS IN NATURAL-WATERS AND BLOOD [J].
BATLEY, GE ;
FARRAR, YJ .
ANALYTICA CHIMICA ACTA, 1978, 99 (02) :283-292
[2]  
BOND AM, 1984, ANAL CHIM ACTA, V162, P389, DOI 10.1016/S0003-2670(00)84263-4
[3]   RAPID HIGH-PERFORMANCE ANALYTICAL PROCEDURE WITH SIMULTANEOUS VOLTAMMETRIC DETERMINATION OF TOXIC TRACE-METALS IN URINE [J].
GOLIMOWSKI, J ;
VALENTA, P ;
STOEPPLER, M ;
NURNBERG, HW .
TALANTA, 1979, 26 (08) :649-656
[4]  
HAEGERARONSEN B, 1960, SCAND J CLIN LAB INV, V12, P128
[5]   APPLICATION OF POLYMER-COATED GLASSY-CARBON ELECTRODES IN ANODIC-STRIPPING VOLTAMMETRY [J].
HOYER, B ;
FLORENCE, TM ;
BATLEY, GE .
ANALYTICAL CHEMISTRY, 1987, 59 (13) :1608-1614
[6]  
KUBASIK NP, 1973, CLIN CHEM, V19, P954
[7]   ANODIC-STRIPPING VOLTAMMETRY OF HEAVY-METALS IN THE PRESENCE OF ORGANIC SURFACTANTS [J].
KUBIAK, WW ;
WANG, J .
TALANTA, 1989, 36 (08) :821-824
[8]   THE USE OF SWEAT TO MONITOR LEAD ABSORPTION THROUGH THE SKIN [J].
LILLEY, SG ;
FLORENCE, TM ;
STAUBER, JL .
SCIENCE OF THE TOTAL ENVIRONMENT, 1988, 76 (2-3) :267-278
[9]   DETERMINATION OF CADMIUM, LEAD AND COPPER IN URINE BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY [J].
LUND, W ;
ERIKSEN, R .
ANALYTICA CHIMICA ACTA, 1979, 107 (JUN) :37-46
[10]  
SINGERMAN A, 1984, EVALUATION ANAL METH, V4, P38