NORMAL RANGE OF MOTION OF JOINTS IN MALE-SUBJECTS

被引:456
作者
BOONE, DC
AZEN, SP
机构
[1] ORTHOPAED HOSP,LOS ANGELES,CA 90007
[2] UNIV SO CALIF,SCH MED,DEPT COMMUNITY & FAMILY MED,LOS ANGELES,CA 90007
关键词
D O I
10.2106/00004623-197961050-00017
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
With a clinical goniometer, the authors measured the arcs of active motion of the shoulder, elbow, forearm, wrist, hip, knee, ankle, and foot in 109 normal male subjects ranging in age from eighteen months to fifty-four years old. The normal limits were determined for subjects who were one to nineteen years old. Significant differences were found between the two age groups for most motions. The data were compared with estimations in the handbook of The American Academy of Orthopaedic Surgeons as the standard reference. The data constitute a more detailed set of measurements, based on a sample described according to height and age, than has been available hitherto.
引用
收藏
页码:756 / 759
页数:4
相关论文
共 34 条
  • [1] AHLBACK SVEN-OLOF, 1964, ACTA ORTHOPSCAND, V34, P310
  • [2] NORMAL RANGE OF JOINT MOVEMENTS IN SHOULDER, HIP, WRIST AND THUMB WITH SPECIAL REFERENCE TO SIDE - COMPARISON BETWEEN 2 POPULATIONS
    ALLANDER, E
    BJORNSSON, OJ
    OLAFSSON, O
    SIGFUSSON, N
    THORSTEINSSON, J
    [J]. INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 1974, 3 (03) : 253 - 261
  • [3] [Anonymous], 1965, JOINT MOTION METHOD
  • [4] BONIN GV, 1929, J ANAT, V63, P259
  • [5] RELIABILITY OF GONIOMETRIC MEASUREMENTS
    BOONE, DC
    AZEN, SP
    LIN, CM
    SPENCE, C
    BARON, C
    LEE, L
    [J]. PHYSICAL THERAPY, 1978, 58 (11): : 1355 - 1360
  • [6] UPPER EXTREMITY RANGE OF MOTION, GRIP STRENGTH, AND GIRTH IN HIGHLY SKILLED TENNIS PLAYERS
    CHINN, CJ
    PRIEST, JD
    KENT, BE
    [J]. PHYSICAL THERAPY, 1974, 54 (05): : 474 - 482
  • [7] Clark W., 1920, J ORTHOP SURG, V2, P687
  • [8] CLARKE GR, 1974, ORTHOPAEDICS, V7, P55
  • [9] Cobe HM, 1928, J BONE JOINT SURG, V10, P763
  • [10] COON V, 1975, CLIN ORTHOPAEDICS, V110, P256