INTRACARDIAC ECHOCARDIOGRAPHY IN HUMANS USING A SMALL-SIZED (6F), LOW-FREQUENCY (12.5 MHZ) ULTRASOUND CATHETER - METHODS, IMAGING PLANES AND CLINICAL-EXPERIENCE

被引:61
作者
SCHWARTZ, SL
GILLAM, LD
WEINTRAUB, AR
SANZOBRINO, BW
HIRST, JA
HSU, TL
FISHER, JP
MARX, G
FULTON, D
MCKAY, RG
PANDIAN, NG
机构
[1] TUFTS UNIV,NEW ENGLAND MED CTR,DEPT MED,750 WASHINGTON ST,BOX 32,BOSTON,MA 02111
[2] HARTFORD HOSP,DEPT MED,HARTFORD,CT 06115
关键词
D O I
10.1016/0735-1097(93)90736-K
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. This study was designed to determine the clinical utility and feasibility of using 12.5-MHz ultrasound catheters for intracardiac echocardiography. Background. Intracardiac echocardiography is a potentially useful technique of cardiac imaging and monitoring in certain settings. The feasibility of intracardiac echocardiography using 20-MHz ultrasound catheters in patients has been demonstrated. High resolution images of normal cardiac structures as well as cardiac abnormalities have been obtained. However, imaging has been limited by the shallow depth of field inherent in high frequency ultrasound imaging. Methods. Intracardiac echocardiography with 12.5-MHz catheters was performed in eight mongrel dogs and 92 patients. Catheters were introduced percutaneously in 80 patients studied in the catheterization laboratory and directly into the heart in 12 patients in the operating room. Right heart imaging was performed in 68 patients and arterial and left heart imaging in 35 patients. Results. When these catheters were introduced into the venous system, the right atrium, tricuspid valve, right ventricle, pulmonary valve and pulmonary artery were visualized. Pericardial effusion, intracardiac masses and atrial septal defects were correctly identified. The left ventricle, left atrium, mitral valve, aortic valve, aorta and coronary arteries could be imaged from the arterial circulation. Diseases identified included valvular aortic stenosis, subvalvular aortic stenosis and Kawasaki disease. Average imaging time was 10 min. No complications occurred as a result of intracardiac echocardiography. Conclusions. Intracardiac echocardiography with 12.5-MHz ultrasound catheters is safe and feasible; it also provides anatomic and physiologic information. This feasibility study provides a foundation for wider clinical use of intracardiac echocardiography.
引用
收藏
页码:189 / 198
页数:10
相关论文
共 24 条
[1]  
BERNS E, 1990, Journal of the American College of Cardiology, V15, p19A
[2]  
CIESZYSKI TOMASZ, 1960, ARCH IMMUNOL I TERAP DOSWIADCZALNEJ, V8, P551
[3]   INTRA-CARDIAC M-MODE ECHOCARDIOGRAPHY FOR CONTINUOUS LEFT-VENTRICULAR MONITORING - METHOD AND POTENTIAL APPLICATION [J].
CONETTA, DA ;
CHRISTIE, LG ;
PEPINE, CJ ;
NICHOLS, WW ;
CONTI, CR .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1979, 5 (02) :135-143
[4]   TRANSVENOUS INTRACARDIAC ECHOCARDIOGRAPHY [J].
GLASSMAN, E ;
KRONZON, I .
AMERICAN JOURNAL OF CARDIOLOGY, 1981, 47 (06) :1255-1259
[5]  
GOLI VD, 1991, CIRCULATION S2, V84, P439
[6]   THE M-HEART PERCUTANEOUS BALLOON MITRAL VALVULOPLASTY REGISTRY - INITIAL RESULTS AND EARLY FOLLOW-UP [J].
HERRMANN, HC ;
KLEAVELAND, JP ;
HILL, JA ;
COWLEY, MJ ;
MARGOLIS, JR ;
NOCERO, MA ;
ZALEWSKI, A ;
PEPINE, CJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (06) :1221-1226
[7]   ACUTE CATASTROPHIC COMPLICATIONS OF BALLOON AORTIC VALVULOPLASTY [J].
ISNER, JM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (06) :1436-1444
[8]  
Jaarsma W, 1990, J Am Soc Echocardiogr, V3, P384
[9]   DIAGNOSTIC APPLICATIONS OF ULTRASOUND IN CARDIOLOGY [J].
KOSSOFF, G .
AUSTRALASIAN RADIOLOGY, 1966, 10 (02) :101-&
[10]   LONG-TERM RESULTS OF CATHETER ABLATION OF A POSTEROSEPTAL ACCESSORY ATRIOVENTRICULAR CONNECTION IN 48 PATIENTS [J].
MORADY, F ;
SCHEINMAN, MM ;
KOU, WH ;
GRIFFIN, JC ;
DICK, M ;
HERRE, J ;
KADISH, AH ;
LANGBERG, J .
CIRCULATION, 1989, 79 (06) :1160-1170