DETERMINATION OF LEAD IN WHOLE-BLOOD USING INDUCTIVELY-COUPLED ARGON PLASMA-MASS SPECTROMETRY WITH ISOTOPE-DILUTION

被引:10
作者
PASCHAL, DC
CALDWELL, KL
TING, BG
机构
[1] Division of Environmental Health Laboratory Sciences, Centers for Disease Control and Prevention, US Department of Health and Human Services, Atlanta
关键词
INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY; ISOTOPE DILUTION MASS SPECTROMETRY; LEAD; BLOOD; REFERENCE MATERIALS; TARGET VALUE;
D O I
10.1039/ja9951000367
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An accurate and simple method for determination of lead in whole blood using inductively coupled argon plasma mass source mass spectrometry (ICP-MS) was developed, Determination of lead was by stable isotope dilution, using a spiking material from the National Institute of Standards and Technology (NIST), Standard Reference Material (SRM) 983, Radiogenic Lead Isotopic Standard, enriched to 92.15 at.% lead 206 (Pb-206). Two aliquots of each whole blood specimen were taken (about 0.50 g) and weighed accurately by difference, One of the aliquots was then spiked with about 100 mg of a solution prepared from SRM 983; about 1 mu g g(-1) of Pb in concentration. Both aliquots were then digested with ultrapure, concentrated nitric acid in a microwave oven. The digestate was cooled, diluted, and both unspiked and spiked digests were aspirated into the ICP-MS instrument and isotope ratios of lead 208:lead 206 were measured. The amount and concentration of lead was calculated as mu g of lead per g sample, and multiplied by 100 to give mu g of lead per 100 g of sample, This mass-basis measurement (mu g per 100 g) was then converted to mass per volume (mu g dl(-1)) using the measured density of the whole blood specimen as a correction factor. The method has been evaluated using SRM 955a to determine accuracy, The proposed method provides a standard of accuracy for determination of lead in blood in a nationally based standardization programme, the Blood Lead Laboratory Reference System (BLLRS).
引用
收藏
页码:367 / 370
页数:4
相关论文
共 13 条
[1]  
[Anonymous], 1991, PREVENTING LEAD POIS
[2]   LEAD SEPARATION BY ANODIC DEPOSITION AND ISOTOPE RATIO MASS-SPECTROMETRY OF MICROGRAM AND SMALLER SAMPLES [J].
BARNES, IL ;
MURPHY, TJ ;
GRAMLICH, JW ;
SHIELDS, WR .
ANALYTICAL CHEMISTRY, 1973, 45 (11) :1881-1884
[3]   LEAD AND CHILD-DEVELOPMENT [J].
DAVIS, JM ;
SVENDSGAARD, DJ .
NATURE, 1987, 329 (6137) :297-300
[4]   ISOTOPE-DILUTION MASS-SPECTROMETRY FOR ACCURATE ELEMENTAL ANALYSIS [J].
FASSETT, JD ;
PAULSEN, PJ .
ANALYTICAL CHEMISTRY, 1989, 61 (10) :A643-&
[5]  
KABATAPENDIAS A, 1988, TRACE ELEMENTS SOILS
[6]  
LASZITY A, J ANAL ATOM SPECTROM, V4, P761
[7]  
MACHLAN LA, 1976, NBS SPECIAL PUBLICAT, V422
[8]  
MILLER DT, 1977, ANALYST, V112, P1701
[9]  
MORROW JS, UNPUB
[10]   PRENATAL AND POSTNATAL EFFECTS OF LOW-LEVEL LEAD-EXPOSURE - INTEGRATED SUMMARY OF A REPORT TO THE UNITED-STATES CONGRESS ON CHILDHOOD LEAD-POISONING [J].
MUSHAK, P ;
DAVIS, JM ;
CROCETTI, AF ;
GRANT, LD .
ENVIRONMENTAL RESEARCH, 1989, 50 (01) :11-36