STRAIN-GAUGE PLETHYSMOGRAPHY FOR THE DETECTION OF DEEP VENOUS THROMBOSIS

被引:18
作者
CROAL, S
BIRKMYRE, J
MCNALLY, M
HAMILTON, C
MOLLAN, R
机构
[1] Department of Orthopaedic Surgery, The Queen's University of Belfast, Musgrave Park Hospital, Stockmans Lane
来源
JOURNAL OF BIOMEDICAL ENGINEERING | 1993年 / 15卷 / 02期
关键词
DEEP VENOUS THROMBOSIS; VENOUS OCCLUSION PLETHYSMOGRAPHY; STRAIN GAUGE PLETHYSMOGRAPHY; COMPUTERIZED SCREENER;
D O I
10.1016/0141-5425(93)90043-X
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Deep venous thrombosis is a widely recognized medical problem which results in significant morbidity and mortality. Venography is the current 'gold standard' diagnostic test for deep venous thrombosis; however it is costly, invasive and is unnecessarily performed in 50% of cases. This paper describes a self-contained, non-invasive system for automatic venous occlusion plethysmographic measurement and analysis. An examination of 274 symptomatic limbs was conducted using strain gauge plethysmography and a subsequent venographic examination was then performed. The plethysmographic results were then compared with venography so as to develop a means of discrimination for thrombotic and non-thrombotic limbs. Strain gauge plethysmography using the Belfast DVT Screener yielded a sensitivity of 100% and a sensitivity of 66.3% for proximal segment DVT. The efficacy of the discriminatory algorithm was then tested for the diagnosis of DVT in a further 101 symptomatic patients. A sensitivity of 94.7% and a specificity of 81.7% were observed for strain gauge plethysmography for proximal segment thrombosis in this patient group. The Belfast DVT Screener is highly sensitive for deep venous thrombosis and may be used to reduce the need for venography, which is of benefit to both the patient and clinician.
引用
收藏
页码:135 / 139
页数:5
相关论文
共 17 条
[1]  
ALBRECHTSSON U, 1976, LANCET, V1, P723
[2]  
BOUNAMEAUX H, 1982, THROMB HAEMOSTASIS, V47, P141
[3]  
COMEROTA AJ, 1990, J VASC SURG, V11, P53
[4]  
Cramer M, 1983, BRUIT, V7, P17
[5]   DETECTION OF VENOUS THROMBOSIS OF LEGS USING 125 I-LABELLED FIBRINOGEN [J].
FLANC, C ;
KAKKAR, VV ;
CLARKE, MB .
BRITISH JOURNAL OF SURGERY, 1968, 55 (10) :742-&
[6]   FIBRIN DEGRADATION PRODUCTS AND IMPEDANCE PLETHYSMOGRAPHY - MEASUREMENTS IN THE DIAGNOSIS OF ACUTE DEEP-VEIN THROMBOSIS [J].
FOTI, MEG ;
GUREWICH, V .
ARCHIVES OF INTERNAL MEDICINE, 1980, 140 (07) :903-906
[7]  
HALLBOOK T, 1971, ACTA CHIR SCAND, V137, P37
[8]  
MCGIVERN RC, 1991, AUTOMEDICA, V13, P239
[9]   STRAIN-GAUGE PLETHYSMOGRAPHY IN THE ASSESSMENT OF VENOUS REFLUX AFTER SUBFASCIAL CLOSURE OF PERFORATING VEINS - A PROSPECTIVE-STUDY OF 20 PATIENTS [J].
PERHONIEMI, V ;
SALO, JA ;
HAAPIAINEN, R ;
SALO, H .
JOURNAL OF VASCULAR SURGERY, 1990, 12 (01) :34-37
[10]  
RABINOV K, 1972, ARCH SURG-CHICAGO, V104, P134