INFLUENCE OF MAGNETIC-FIELD STRENGTH ON T2(ASTERISK) DECAY AND PHASE EFFECTS IN GRADIENT-ECHO MRI OF VERTEBRAL BONE-MARROW

被引:19
作者
PARIZEL, PM
VANRIET, B
VANHASSELT, BAAM
VANGOETHEM, JW
VANDENHAUWE, L
DIJKSTRA, HAJ
VANWIECHEN, PJ
DESCHEPPER, AM
机构
[1] SIEMENS AG,MED SYST,BRUSSELS,BELGIUM
[2] IGNATIUS ZIEKENHUIS BREDA,DEPT RADIOL,BREDA,BELGIUM
关键词
MAGNETIC RESONANCE IMAGING; TECHNIQUES; PHYSICS;
D O I
10.1097/00004728-199505000-00023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The goal of this study was twofold: first, to quantify the influence of magnetic field strength (B-0) on T2* and T2(susceptibility) relaxation rates in vertebral bone marrow; and second, to determine the significance of in-phase/out-of-phase phenomena in GE MRI as a function of TEs at different B-0 values. Materials and Methods: Magnetic resonance imaging of the spine was performed at 1.5, 1.0, and 0.2 T using a GE sequence (2D-FLASH) with variable TE. Vertebral body signal intensities were measured and plotted against TE values. These curves were used to calculate T2* decay of bone marrow at different B-0 values. Results: At all field strengths, we observed exponential signal decay, modulated by a cosine function, the periodicity of which was proportional to B-0. The T2* values of vertebral bodies were 9.7 +/- 1.8 ms at 1.5 T, 17.2 +/- 2.4 ms at 1.0 T, and 53 +/- 5 ms at 0.2 T. True T2 relaxation time (independent of field strength) was 62 +/- 4 ms. The T2(susceptibility) was 11.7 ms at 1.5 T, 24.8 ms at 1.0 T, and 585 ms at 0.2 T. Conclusion: We conclude that at low B-0, susceptibility effects become less important and T2* approaches true T2 relaxation.
引用
收藏
页码:465 / 471
页数:7
相关论文
共 15 条
[1]   FAT FRACTION OF LUMBAR BONE-MARROW USING INVIVO PROTON NUCLEAR-MAGNETIC-RESONANCE SPECTROSCOPY [J].
DEBISSCHOP, E ;
LUYPAERT, R ;
LOUIS, O ;
OSTEAUX, M .
BONE, 1993, 14 (02) :133-136
[2]   INVIVO QUANTITATIVE CHARACTERIZATION OF TRABECULAR BONE BY NMR INTERFEROMETRY AND LOCALIZED PROTON SPECTROSCOPY [J].
FORD, JC ;
WEHRLI, FW .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) :543-551
[3]   FLASH IMAGING - RAPID NMR IMAGING USING LOW FLIP-ANGLE PULSES [J].
HAASE, A ;
FRAHM, J ;
MATTHAEI, D ;
HANICKE, W ;
MERBOLDT, KD .
JOURNAL OF MAGNETIC RESONANCE, 1986, 67 (02) :258-266
[4]  
Hendrick R. E., 1992, MAGNETIC RESONANCE I, P109
[5]   QUANTITATION OF THE SUSCEPTIBILITY DIFFERENCE BETWEEN TRABECULAR BONE AND BONE-MARROW - EXPERIMENTAL STUDIES [J].
MAJUMDAR, S ;
THOMASSON, D ;
SHIMAKAWA, A ;
GENANT, HK .
MAGNETIC RESONANCE IN MEDICINE, 1991, 22 (01) :111-127
[6]   LIPID-WATER RATIO OF BONE-MARROW MEASURED BY PHASE-ENCODED PROTON NUCLEAR-MAGNETIC-RESONANCE SPECTROSCOPY [J].
RICHARDS, TL ;
DAVIS, CA ;
BARKER, BR ;
BEINERT, WD ;
GENANT, HK .
INVESTIGATIVE RADIOLOGY, 1987, 22 (09) :741-746
[7]  
SEIDERER M, 1993, 8TH EUR C RAD, P172
[8]   A METHOD FOR CHEMICAL-SHIFT IMAGING - DEMONSTRATION OF BONE-MARROW INVOLVEMENT WITH PROTON CHEMICAL-SHIFT IMAGING [J].
SEPPONEN, RE ;
SIPPONEN, JT ;
TANTTU, JI .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) :585-587
[9]   BONE-MARROW DISORDERS - CHARACTERIZATION WITH QUANTITATIVE MR IMAGING [J].
SMITH, SR ;
WILLIAMS, CE ;
DAVIES, JM ;
EDWARDS, RHT .
RADIOLOGY, 1989, 172 (03) :805-810
[10]   DIFFERENTIAL-DIAGNOSIS OF BENIGN AND MALIGNANT VERTEBRAL COMPRESSION FRACTURES WITH MR IMAGING - VALUE OF ANTIPHASED LONG TR GRADIENT-ECHO SEQUENCES, STIR SEQUENCES AND GD-DTPA [J].
STABLER, A ;
KRIMMEL, K ;
SEIDERER, M ;
GARTNER, C ;
FRITSCH, S ;
RAUM, W .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 157 (03) :215-221