SIGNAL DURATION AND SIGNAL FREQUENCY IN RELATION TO AUDITORY SENSITIVITY

被引:170
作者
WATSON, CS
GENGEL, RW
机构
[1] Central Institute for the Deaf, St. Louis
关键词
D O I
10.1121/1.1911819
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Levels of monaural signals at behavioral threshold were determined by a psychophysical method of adjustment for seven highly trained listeners. Thresholds were studied as a function of signal frequency (octave steps, from 0.125 to 8 kHz) and of signal duration (logarithmic steps, from 16 to 1024 msec). Measurements were made in the presence of a contralateral broad band masking noise with a spectrum level of 30 dB SPL. The time constant, τ estimated from at least 12 replications of each measurement, was found to range systematically from values considered normal (125 175 msec) by some earlier investigators, at low frequencies, to much lower values (30 70 msec) at high frequencies. Comparison between the performance of listeners with normal audiograms and those with high frequency hearing loss shows this interaction between frequency and the time constant to be similar for both samples. The data are also compared to the results of a second experiment that employed a two alternative forced choice psychophysical method. © 1969, Acoustical Society of America. All rights reserved.
引用
收藏
页码:989 / &
相关论文
共 26 条