FLOW-INJECTION ANALYSIS OF WATER .1. AUTOMATIC PRECONCENTRATION DETERMINATION OF SULFATE, AMMONIA AND IRON(II) IRON(III)

被引:15
作者
COSANO, JS
DECASTRO, MDL
VALCARCEL, M
机构
[1] Department of Analytical Chemistry, Faculty of Sciences, University of Córdoba
来源
JOURNAL OF AUTOMATIC CHEMISTRY | 1993年 / 15卷 / 04期
关键词
D O I
10.1155/S1463924693000185
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper describes a simple flow-injection (FI) manifold for the determination of a variety of species in industrial water. The chemical systems involved in the determination of ammonia (formation of Indophenol Blue), sulfate (precipitation with Ba(II)), and iron (complexation with 1,10-phenanthroline with the help of a prior redox reaction for speciation) were selected so that a common manifold could be used for the sequential determination of batches of each analyte. A microcolumn of a suitable ion exchange material was used for on-line preconcentration of each analyte prior to injection; linear ranges for the determination of the analytes at the ng/ml levels were obtained with good reproducibility. The manifold and methods are ready for full automation.
引用
收藏
页码:141 / 146
页数:6
相关论文
共 18 条
[1]  
BERTHELOT MEP, 1859, REPORT CHEM APPLIQUE, V284
[2]   AN AUTOMATED SPECTROPHOTOMETRIC FIELD-MONITOR FOR WATER-QUALITY PARAMETERS - DETERMINATION OF AMMONIA [J].
CLINCH, JR ;
WORSFOLD, PJ ;
SWEETING, FW .
ANALYTICA CHIMICA ACTA, 1988, 214 (1-2) :401-407
[3]   DETERMINATION OF TRACE LEVELS OF SULFATE IN WATER USING FLOW-INJECTION AND IN-LINE PRECONCENTRATION [J].
KARLSSON, M ;
PERSSON, JA ;
MOLLER, J .
ANALYTICA CHIMICA ACTA, 1991, 244 (01) :109-113
[4]   DETERMINATION OF SULFATE IN RIVER WATER BY FLOW-INJECTION ANALYSIS [J].
KONDO, O ;
MIYATA, H ;
TOEI, K .
ANALYTICA CHIMICA ACTA, 1982, 134 (JAN) :353-358
[5]   RAPID-DETERMINATION OF SULFATE IN NATURAL-WATERS AND PLANT DIGESTS BY CONTINUOUS-FLOW INJECTION TURBIDIMETRY [J].
KRUG, FJ ;
FILHO, HB ;
ZAGATTO, EAG ;
JORGENSEN, SS .
ANALYST, 1977, 102 (1216) :503-508
[6]   DETERMINATION OF SULFATE IN NATURAL-WATER BY FLOW-INJECTION ANALYSIS [J].
NAKASHIMA, S ;
YAGI, M ;
ZENKI, M ;
DOI, M ;
TOEI, K .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1984, 317 (01) :29-31
[7]   DETERMINATION OF AMMONIUM ION IN A FLOW-INJECTION SYSTEM WITH A GAS-DIFFUSION MEMBRANE - SELECTION OF OPTIMAL CONDITIONS FOR THE PH INDICATOR [J].
NAKATA, R ;
KAWAMURA, T ;
SAKASHITA, H ;
NITTA, A .
ANALYTICA CHIMICA ACTA, 1988, 208 (1-2) :81-90
[8]  
PERSSON GORAN A., 1966, AIR WATER POLLUT, V10, P845
[9]   FLOW-THROUGH DETERMINATION OF SULFATE IN WATER USING DIFFERENT METHODS - COMPARISON [J].
REIJNDERS, HFR ;
VANSTADEN, JJ ;
GRIEPINK, B .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1980, 300 (04) :273-276
[10]   PHOTOMETRY IN A CONTINUOUS-FLOW SYSTEM - DETERMINATION OF SULFATE IN A CONTINUOUS-FLOW SYSTEM IN ENVIRONMENTAL-SAMPLES WITH DIMETHYLSULPHONAZO(III) [J].
REIJNDERS, HFR ;
VANSTADEN, JJ ;
GRIEPINK, B .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1979, 295 (2-3) :122-124