EFFECTS OF ELECTROMYOGRAPHIC PROCESSING METHODS ON COMPUTER-AVERAGED SURFACE ELECTROMYOGRAPHIC PROFILES FOR THE GLUTEUS-MEDIUS MUSCLE

被引:27
作者
KLEISSEN, RFM
机构
来源
PHYSICAL THERAPY | 1990年 / 70卷 / 11期
关键词
Computers; Electromyography; Kinesiology/biomechanics; gait analysis; Muscle performance; general; Tests and measurements; electrodiagnosis;
D O I
10.1093/ptj/70.11.716
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The objective of this study was to demonstrate how two different linear envelope detectors, as used in the quantification of surface electromyographic (EMG) signals, can lead to differences in the properties of observed computer-averaged EMG profiles. Eight healthy male subjects, aged 24 to 32 years, participated in the study. Computer-averaged EMG profiles for the gluteus medius muscle were recorded at a free-walking cadence and at stepping frequencies of 78 and 120 steps/min, using detectors with 3- and 25-Hz cutoff frequencies simultaneously. The 3-Hz filtered EMG profiles proved to be smoother, to exhibit a significantly lower cycle-to-cycle variability, and to have a greater time lag with respect to the original unprocessed EMG signal than the 25-Hz filtered EMG profiles. The observed inter-subject variability also was lower for the 3-Hz filtered EMG profiles than for the 25-Hz filtered EMG profiles. The results indicate that comparison of EMG profiles recorded with different detectors is difficult. A standard detector may solve this difficulty. [Kleissen RFM. Effects of electromyographic processing methods on computer-averaged surface electromyographic profiles for the gluteus medius muscle.]
引用
收藏
页码:716 / 722
页数:7
相关论文
共 16 条
[1]   IS THERE A NORMAL PROFILE OF EMG ACTIVITY IN GAIT [J].
ARSENAULT, AB ;
WINTER, DA ;
MARTENIUK, RG .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1986, 24 (04) :337-343
[2]   EMG-FORCE DYNAMICS IN HUMAN SKELETAL MUSCLE [J].
COGGSHALL, JC ;
BEKEY, GA .
MEDICAL & BIOLOGICAL ENGINEERING, 1970, 8 (03) :265-+
[4]  
ERICSON MO, 1986, SCAND J REHABIL MED, V18, P159
[5]  
HUMPHREYS DS, 1970, ANAL DESIGN SYNTHESI, P38
[6]  
KADEFORS R, 1973, NEW DEV EMG CLIN NEU, V1, P519
[7]   SIMULTANEOUS MEASUREMENT OF SURFACE EMG AND MOVEMENTS FOR CLINICAL USE [J].
KLEISSEN, RFM ;
HERMENS, HJ ;
DENEXTER, T ;
DEKREEK, JA ;
ZILVOLD, G .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1989, 27 (03) :291-297
[8]  
KLEISSEN RFM, 1989, 12TH P INT C BIOM LO
[9]  
KNUTSSON E, 1981, SCAND J REHABIL MED, V13, P101
[10]   BIOMECHANICS OF BELOW-KNEE AMPUTEE GAIT [J].
WINTER, DA ;
SIENKO, SE .
JOURNAL OF BIOMECHANICS, 1988, 21 (05) :361-367