THE USEFULNESS OF ULTRASONOGRAPHY IN INTRACAVITARY RADIOTHERAPY USING SELECTRON APPLICATORS

被引:9
作者
WONG, F [1 ]
BHIMJI, S [1 ]
机构
[1] CANC CONTROL AGCY,A MAXEWELL EVANS CLIN,DEPT RADIOL,VANCOUVER V5Z 4E6,BC,CANADA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1990年 / 19卷 / 02期
关键词
intracavitary; perforation; Therapeutic radiology; therapeutic radiology; ultrasonography; Uterine neoplasms; Uterus;
D O I
10.1016/0360-3016(90)90560-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Uterine perforation can occur during the procedure of intracavitary insertions for the treatment of carcinoma of the cervix. If radiation treatment proceeds in the situation of inadvertent perforation, severe complication may result. The ultrasonographic studies of five patients with metal intrauterine applicators in situ are described. The applicator appeared as a linear echogenic density within the uterine cavity. The thickness of the uterine wall and the fundus could be clearly identified in a normal insertion. In the presence of uterine perforation, the applicator was seen traversing the myometrium necessitating alteration of the treatment plan. © 1990.
引用
收藏
页码:477 / 482
页数:6
相关论文
共 9 条
[1]   USE OF ULTRASONOGRAPHY IN PLANNING INTRACAVITARY RADIOTHERAPY OF ENDOMETRIAL CARCINOMA [J].
BRASCHO, DJ ;
KIM, RY ;
WILSON, EE .
RADIOLOGY, 1978, 129 (01) :163-167
[2]   A CT BASED DOSIMETRY SYSTEM FOR INTRACAVITARY THERAPY IN CARCINOMA OF THE CERVIX [J].
COLTART, RS ;
NETHERSELL, ABW ;
THOMAS, S ;
DIXON, AK .
RADIOTHERAPY AND ONCOLOGY, 1987, 10 (04) :295-305
[3]   ULTRASOUND USED FOR ASSESSING THE INSITU POSITION OF INTRAUTERINE TANDEMS [J].
GRANAI, CO ;
ALLEE, P ;
DOHERTY, F ;
MADOCJONES, H ;
CURRY, SL .
GYNECOLOGIC ONCOLOGY, 1984, 18 (03) :334-338
[4]   UTERINE PERFORATION DURING INTRACAVITARY APPLICATION - PROGNOSTIC-SIGNIFICANCE IN CARCINOMA OF THE CERVIX [J].
KIM, RY ;
LEVY, DS ;
BRASCHO, DJ ;
HATCH, KD .
RADIOLOGY, 1983, 147 (01) :249-251
[5]   CT FOR INTRACAVITARY RADIOTHERAPY PLANNING [J].
LEE, KR ;
MANSFIELD, CM ;
DWYER, SJ ;
COX, HL ;
LEVINE, E ;
TEMPLETON, AW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1980, 135 (04) :809-813
[6]   CT SCANNING IN INTRACAVITARY THERAPY - UNEXPECTED FINDINGS IN STRAIGHTFORWARD INSERTIONS [J].
MAKIN, WP ;
HUNTER, RD .
RADIOTHERAPY AND ONCOLOGY, 1988, 13 (04) :253-255
[7]   UTERINE PERFORATION AT THE TIME OF BRACHYTHERAPY FOR THE CARCINOMA OF THE UTERINE CERVIX [J].
MATSUYAMA, T ;
TSUKAMOTO, N ;
MATSUKUMA, K ;
KAMURA, T ;
JINGU, K .
GYNECOLOGIC ONCOLOGY, 1986, 23 (02) :205-211
[8]  
REDDI PR, 1974, OBSTET GYNECOL, V43, P238
[9]   THE USE OF SELECTRON AFTERLOADING EQUIPMENT TO SIMULATE AND EXTEND THE MANCHESTER SYSTEM FOR INTRACAVITARY THERAPY OF THE CERVIX UTERI [J].
WILKINSON, JM ;
MOORE, CJ ;
NOTLEY, HM ;
HUNTER, RD .
BRITISH JOURNAL OF RADIOLOGY, 1983, 56 (666) :409-414