学术探索
学术期刊
新闻热点
数据分析
智能评审
立即登录
COMPARISON OF THROMBOPLASTINS USING THE ISI AND INR SYSTEM
被引:28
作者
:
MORIARTY, HT
论文数:
0
引用数:
0
h-index:
0
机构:
PRINCE WALES HOSP,DEPT HAEMATOL,HIGH ST,RANDWICK,NSW 2031,AUSTRALIA
PRINCE WALES HOSP,DEPT HAEMATOL,HIGH ST,RANDWICK,NSW 2031,AUSTRALIA
MORIARTY, HT
[
1
]
LAMPOTANG, PRL
论文数:
0
引用数:
0
h-index:
0
机构:
PRINCE WALES HOSP,DEPT HAEMATOL,HIGH ST,RANDWICK,NSW 2031,AUSTRALIA
PRINCE WALES HOSP,DEPT HAEMATOL,HIGH ST,RANDWICK,NSW 2031,AUSTRALIA
LAMPOTANG, PRL
[
1
]
ANASTAS, N
论文数:
0
引用数:
0
h-index:
0
机构:
PRINCE WALES HOSP,DEPT HAEMATOL,HIGH ST,RANDWICK,NSW 2031,AUSTRALIA
PRINCE WALES HOSP,DEPT HAEMATOL,HIGH ST,RANDWICK,NSW 2031,AUSTRALIA
ANASTAS, N
[
1
]
机构
:
[1]
PRINCE WALES HOSP,DEPT HAEMATOL,HIGH ST,RANDWICK,NSW 2031,AUSTRALIA
来源
:
PATHOLOGY
|
1990年
/ 22卷
/ 02期
关键词
:
International Normalized Ratio;
International Sensitivity Index;
Prothrombin time;
Thromboplastins;
D O I
:
10.3109/00313029009063783
中图分类号
:
R36 [病理学];
学科分类号
:
100104 ;
摘要
:
Twelve thromboplastins were tested against a secondary reference thromboplastin (human brain CRM BCR No. 147) or a tertiary house standard (human brain thromboplastin) with plasmas from normal healthy individuals and patients on oral anticoagulant therapy. The relationship between the prothrombin ratios of the thromboplastins tested versus the reference reagent was either a straight or curved line. The International Sensitivity Index (ISI) was estimated for each of the test thromboplastins and these ranged from 0.98 to 2.24. Some ISIs stated by manufacturers were different from our results. Thromboplastins with a high ISI showed a loss of sensitivity in assessing the level of anticoagulation at the upper end of the therapeutic range. In addition, the 95% Confidence Interval (CI) of the ISI estimations were widest for thromboplastins with the highest ISIs. Conversion of the prothrombin ratio to International Normalized Ratio (INR) was most accurate with the Australasian Reference Thromboplastin (ART) and least accurate with reagents having an ISI of 2.00 and over. Thromboplastins with an ISI between 1.10 and 1.50 may be adequate for the control of oral anticoagulant therapy, but were less accurate than a thromboplastin with an ISI approximating 1.00. Factors other than ISI should be considered in the choice of a thromboplastin, in particular a measurement of the accuracy of the ISI estimation such as the 95% confidence interval estimation used here. © 1990 Royal College of Pathologists of Australasia.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 6 条
[1]
LAMPOTANG PRL, 1986, ADV COAGULATION TEST, P365
[2]
SURVEY OF PROTHROMBIN TIME IN NATIONAL-EXTERNAL-QUALITY-ASSESSMENT-SCHEME EXERCISES (1980-87)
POLLER, L
论文数:
0
引用数:
0
h-index:
0
POLLER, L
TABERNER, DA
论文数:
0
引用数:
0
h-index:
0
TABERNER, DA
THOMSON, JM
论文数:
0
引用数:
0
h-index:
0
THOMSON, JM
DARBY, KV
论文数:
0
引用数:
0
h-index:
0
DARBY, KV
[J].
JOURNAL OF CLINICAL PATHOLOGY,
1988,
41
(04)
: 361
-
364
[3]
QUICK AJ, 1935, J BIOL CHEM, V109, pR23
[4]
1981, RECOMMENDED METHODOL
[5]
1983, TECH REP SERIES, V687, P81
[6]
1985, THROMB HEMOST, V53, P155
←
1
→
共 6 条
[1]
LAMPOTANG PRL, 1986, ADV COAGULATION TEST, P365
[2]
SURVEY OF PROTHROMBIN TIME IN NATIONAL-EXTERNAL-QUALITY-ASSESSMENT-SCHEME EXERCISES (1980-87)
POLLER, L
论文数:
0
引用数:
0
h-index:
0
POLLER, L
TABERNER, DA
论文数:
0
引用数:
0
h-index:
0
TABERNER, DA
THOMSON, JM
论文数:
0
引用数:
0
h-index:
0
THOMSON, JM
DARBY, KV
论文数:
0
引用数:
0
h-index:
0
DARBY, KV
[J].
JOURNAL OF CLINICAL PATHOLOGY,
1988,
41
(04)
: 361
-
364
[3]
QUICK AJ, 1935, J BIOL CHEM, V109, pR23
[4]
1981, RECOMMENDED METHODOL
[5]
1983, TECH REP SERIES, V687, P81
[6]
1985, THROMB HEMOST, V53, P155
←
1
→