CLASSIFICATION AND DEFINITION OF ANALYTICAL METHODS BASED ON FLOWING MEDIA - (IUPAC RECOMMENDATIONS 1994)

被引:21
作者
VANDERLINDEN, WE
机构
[1] Laboratory for Chemical Analysis, Department of Chemical Technology, University of Twente, AE Enschede, P.O. Box 217
关键词
D O I
10.1351/pac199466122493
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The aim of this report is to classify analytical methods based on flowing media and to define (standardize) terminology. After the classification and a discussion of terms describing the systems and component parts, a section is devoted to terms describing the performance of flow systems. The list of terms included is restricted to the most relevant ones; especially 'self-explanatory' terms are left out. It is emphasised that the usage of terms or expressions that not adequately describe the processes or procedures involved should be strongly discouraged. Although belonging to the category of methods based on flowing media, chromatographic methods are not comprised in the present document. However, care has been taken that the present text is not in conflict with definitions in that domain. In documents in which flow methods are described, it should be clearly indicated how the sample and/or reagent is introduced and how the sample zone is transported. When introducing new techniques in the field, or variants of existing techniques, it is strongly recommended that descriptive terms rather than trivial or elaborate names are used.
引用
收藏
页码:2493 / 2500
页数:8
相关论文
共 14 条
[1]  
BURNS DT, 1989, ANAL CHIM ACTA, V225, P123
[2]   NOMENCLATURE FOR SAMPLING IN ANALYTICAL-CHEMISTRY - (RECOMMENDATIONS 1990) [J].
HORWITZ, W .
PURE AND APPLIED CHEMISTRY, 1990, 62 (06) :1193-1208
[3]   MATHEMATICAL-MODELING OF SINGLE-LINE FLOW-INJECTION ANALYSIS SYSTEMS WITHOUT CHEMICAL-REACTION [J].
KOLEV, SD ;
PUNGOR, E .
ANALYTICAL CHEMISTRY, 1988, 60 (17) :1700-1709
[4]  
Levenspiel O., 1998, CHEM REACTION ENG
[5]   APPLICATION OF SILICONE RUBBER-BASED GRAPHITE ELECTRODES FOR CONTINUOUS FLOW MEASUREMENTS .2. VOLTAMMETRIC STUDY OF ACTIVE SUBSTANCES INJECTED INTO ELECTROLYTE STREAMS [J].
NAGY, G ;
FEHER, Z ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1970, 52 (01) :47-&
[6]  
NEUE U, 1982, CHROMATOGRAPHIA, V15, P403
[7]   MONOSEGMENTED SYSTEM FOR CONTINUOUS-FLOW ANALYSIS - SPECTROPHOTOMETRIC DETERMINATION OF CHROMIUM(VI), AMMONIA, AND PHOSPHORUS [J].
PASQUINI, C ;
DEOLIVEIRA, WA .
ANALYTICAL CHEMISTRY, 1985, 57 (13) :2575-2579
[8]   DISPERSION IN OPEN TUBES AND TUBES PACKED WITH LARGE GLASS-BEADS - THE SINGLE BEAD STRING REACTOR [J].
REIJN, JM ;
VANDERLINDEN, WE ;
POPPE, H .
ANALYTICA CHIMICA ACTA, 1981, 123 (JAN) :229-237
[9]   TRANSPORT PHENOMENA IN FLOW-INJECTION ANALYSIS WITHOUT CHEMICAL-REACTION [J].
REIJN, JM ;
VANDERLINDEN, WE ;
POPPE, H .
ANALYTICA CHIMICA ACTA, 1981, 126 (MAY) :1-13
[10]   SOME THEORETICAL ASPECTS OF FLOW-INJECTION ANALYSIS [J].
REIJN, JM ;
VANDERLINDEN, WE ;
POPPE, H .
ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) :105-118