AORTIC-VALVE REPLACEMENT WITH AUTOLOGOUS PERICARDIUM - SURGICAL TECHNIQUE

被引:44
作者
DURAN, CMG
GALLO, R
KUMAR, N
机构
[1] Department of Cardiovascular Diseases, King Faisal Specialist Hospital and Research Centre, Riyadh
关键词
D O I
10.1111/j.1540-8191.1995.tb00582.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The surgical technique of aortic valve replacement with freehand glutaraldehyde-treated autologous pericardium is described. Forty-nine patients underwent this procedure without hospital mortality and no thromboembolic episodes without anticoagulation. Three patients underwent reoperation: for infective endocarditis in two; and tear of one commissure 8 months after surgery in another. This technique because of its excellent hemodynamics and low thrombogenicity might be a valid alternative particularly in patients with a small aortic annulus.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 13 条
[1]  
Mercer JL, Benedicty M, Bahnson HT, The geometry and construction of the aortic leaflet, J Thorac Cardiovasc Surg, 65, pp. 511-518, (1973)
[2]  
Swanson M, Clark RE, Dimensions and geometric relationships of the human aortic valve as a function of pressure, Circ Res, 35, pp. 871-882, (1974)
[3]  
Brewer RJ, Deck D, Capati B, Et al., The dynamic aortic root. Its role in aortic valve function, J Thorac Cardiovasc Surg, 72, pp. 413-418, (1976)
[4]  
Thubrikar M, Piepgrass WC, Shaner TW, Et al., The design of the normal aortic valve, Am J Physiol, 241, pp. 795-801, (1981)
[5]  
Silver MA, Roberts WC, Detailed anatomy of the normally functioning aortic valve in hearts of normal and increased weight, Am J Cardiol, 55, pp. 454-461, (1985)
[6]  
Ross DN, Surgical reconstruction of the aortic valve, Lancet, 1, pp. 571-574, (1963)
[7]  
Bjork VO, Hultquist G, Teflon and pericardial aortic valve prosthesis, J Thorac Cardiovasc Surg, 47, pp. 693-702, (1964)
[8]  
Sterling Edwards W, Aortic valve replacement with autogenous tissue, Ann Thorac Surg, 8, pp. 126-132, (1969)
[9]  
Bahnson HT, Hardesty RL, Baker LD, Et al., Fabrication and evaluation of tissue leaflets for aortic and mitral valve replacement, Ann Surg, 171, pp. 939-947, (1970)
[10]  
Yacoub M, Khaghani A, Dhalla N, Et al., Aortic valve replacement using unstented dura or calf pericardium: Early and medium term results, Biological and Bioprosthetic Valves, pp. 684-690, (1986)