BIOELECTRICAL-IMPEDANCE ANALYSIS AS AN ASSESSMENT OF DIURESIS IN CONGESTIVE-HEART-FAILURE

被引:18
作者
COODLEY, EL [1 ]
SEGAL, JL [1 ]
SMITH, DHG [1 ]
NEUTEL, JM [1 ]
机构
[1] VET AFFAIRS MED CTR, MED SERV, LONG BEACH, CA 90822 USA
关键词
D O I
10.1177/106002809502901103
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
OBJECTIVE: TO compare changes in bioimpedance parameters and calculated total body water (TBW) with conventional measurements used to assess the efficacy of diuretic therapy in the treatment of heart failure. SETTING: A Veterans Affairs tertiary care, teaching hospital. SUBJECTS: Twelve patients with New York Heart Association (NYHA) class III congestive heart failure (CHF). DESIGN: Prospective, consecutive sample, cohort, open label. INTERVENTIONS: Parenterally administered furosemide; clinically dictated, outcome-oriented, adjunctive therapy of CHF. OUTCOMES: Bioelectrical impedance analysis (BIA) parameters, measured volume of diuresis and changes in body weight, defined clinical endpoints (NYHA criteria). RESULTS: Three days of diuretic therapy with furosemide (oral and/or intravenous) for CHF was associated with a measured weight loss of 4.1 +/- 0.6 kg and statistically significant increases in resistance and reactance of 20.8% +/- 2.7% and 22.7% +/- 6.1%, respectively (p < 0.005). Calculated TBW using BIA parameters and standard equations decreased on average by 6.1 +/- 0.6 L or 11.2% +/- 1.1% (p < 0.001). A significant inverse correlation was observed between change in measured body weight and total body reactance (p = 0.02). CONCLUSIONS: Single-frequency BIA appears to have limited clinical usefulness as a method of assessing diuretic therapy in the management of CHF. Its greatest usefulness appears to lie in the assessment of serial changes in individual patients and patient populations that are physiologically or metabolically homogeneous. Further studies are needed to establish the validity of BIA in patients with decompensated CHF.
引用
收藏
页码:1091 / 1095
页数:5
相关论文
共 23 条
[1]   ELECTRICAL-IMPEDANCE IN ASSESSING HUMAN-BODY COMPOSITION - THE BIA METHOD [J].
ABUKHALED, M ;
MCCUTCHEON, MJ ;
REDDY, S ;
PEARMAN, PL ;
HUNTER, GR ;
WEINSIER, RL .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1988, 47 (05) :789-792
[2]  
CHUMLEA WC, 1994, NUTR REV, V52, P123, DOI 10.1111/j.1753-4887.1994.tb01404.x
[3]  
GUO S, 1987, HUM BIOL, V59, P221
[4]   CORRELATION OF WHOLE-BODY IMPEDANCE WITH TOTAL BODY WATER VOLUME [J].
HOFFER, EC ;
MEADOR, CK ;
SIMPSON, DC .
JOURNAL OF APPLIED PHYSIOLOGY, 1969, 27 (04) :531-&
[5]  
JOHNSON HL, 1987, FED PROC, V46, P1185
[6]   ESTIMATION OF TOTAL-BODY WATER BY BIOELECTRICAL IMPEDANCE ANALYSIS [J].
KUSHNER, RF ;
SCHOELLER, DA .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1986, 44 (03) :417-424
[7]   VALIDATION OF TETRAPOLAR BIOELECTRICAL IMPEDANCE METHOD TO ASSESS HUMAN-BODY COMPOSITION [J].
LUKASKI, HC ;
BOLONCHUK, WW ;
HALL, CB ;
SIDERS, WA .
JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (04) :1327-1332
[8]   ASSESSMENT OF FAT-FREE MASS USING BIOELECTRICAL IMPEDANCE MEASUREMENTS OF THE HUMAN-BODY [J].
LUKASKI, HC ;
JOHNSON, PE ;
BOLONCHUK, WW ;
LYKKEN, GI .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1985, 41 (04) :810-817
[9]  
LUKASKI HC, 1986, SEP S INT S IN VIV B
[10]  
MCDOUGALL D, 1986, Surgical Forum (Chicago), V37, P42