COMPUTER-DISPLAYED EYE POSITION AS A VISUAL AID TO PULMONARY NODULE INTERPRETATION

被引:76
作者
KUNDEL, HL
NODINE, CF
KRUPINSKI, EA
机构
[1] Department of Radiology, University of Pennsylvania, Philadelphia, PA
关键词
Computer aids; Diagnostic radiology; Lung nodules; Observer performance; Visual feedback; Visual perception;
D O I
10.1097/00004424-199008000-00004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Approximately 30% of nodules are missed during the initial reading of chest radiographs. Eye-position recordings have shown that most nodules that are missed receive prolonged visual attention. A computer algorithm was developed that uses eyeposition and gaze-duration times to identify locations on the chest image likely to contain missed nodules. These locations are highlighted on the displayed image to give visual feedback. The current study tested whether visual feedback was an effective aid to nodule detection. Six radiology residents searched 40 chest images for nodules while their eye-position and gazeduration times were recorded. Half received displayed visual feedback and half were given a second view without feedback. Two months later the two groups returned and viewed the images in the opposite condition to counterbalance for possible practice effects. Performance of readers who were given feedback showed an average of 16% improvement as measured by the alternative free response operating characteristic (AFROC) curve area, A,. Performance of the same readers given a second look without feedback did not improve. © Lippincott-Raven Publishers.
引用
收藏
页码:890 / 896
页数:7
相关论文
共 25 条
[1]  
ANDERSON S, 1980, STATISTICAL METHODS, P199
[2]   INFLUENCE OF CLINICAL HISTORY UPON DETECTION OF NODULES AND OTHER LESIONS [J].
BERBAUM, KS ;
FRANKEN, EA ;
DORFMAN, DD ;
BARLOON, TJ .
INVESTIGATIVE RADIOLOGY, 1988, 23 (01) :48-55
[3]   PERFORMANCE OF A COMPUTER-SYSTEM FOR RECORDING EYE FIXATIONS USING LIMBUS REFLECTION [J].
CARMODY, DP ;
KUNDEL, HL ;
NODINE, CF .
BEHAVIOR RESEARCH METHODS & INSTRUMENTATION, 1980, 12 (01) :63-66
[4]   GLOBAL AND SEGMENTED SEARCH FOR LUNG NODULES OF DIFFERENT EDGE GRADIENTS [J].
CARMODY, DP ;
NODINE, CF ;
KUNDEL, HL .
INVESTIGATIVE RADIOLOGY, 1980, 15 (03) :224-233
[5]   MAXIMUM-LIKELIHOOD ANALYSIS OF FREE-RESPONSE RECEIVER OPERATING CHARACTERISTIC (FROC) DATA [J].
CHAKRABORTY, DP .
MEDICAL PHYSICS, 1989, 16 (04) :561-568
[6]   INTERACTIVE, MATHEMATICAL, AND SEQUENTIAL CONSULTATIVE METHODS IN DIAGNOSING RENAL MASSES ON EXCRETORY UROGRAMS [J].
FERRELL, WR ;
HILLMAN, BJ ;
BREWER, ML ;
AMENDOLA, MA ;
THORNBURY, JR .
INVESTIGATIVE RADIOLOGY, 1989, 24 (06) :456-462
[7]   ENHANCED INTERPRETATION OF DIAGNOSTIC IMAGES [J].
GETTY, DJ ;
PICKETT, RM ;
DORSI, CJ ;
SWETS, JA .
INVESTIGATIVE RADIOLOGY, 1988, 23 (04) :240-252
[8]   IMAGE FEATURE ANALYSIS AND COMPUTER-AIDED DIAGNOSIS IN DIGITAL RADIOGRAPHY .3. AUTOMATED DETECTION OF NODULES IN PERIPHERAL LUNG FIELDS [J].
GIGER, ML ;
DOI, K ;
MACMAHON, H .
MEDICAL PHYSICS, 1988, 15 (02) :158-166
[9]   IMPROVING PERFORMANCE BY MULTIPLE INTERPRETATIONS OF CHEST RADIOGRAPHS - EFFECTIVENESS AND COST [J].
HESSEL, SJ ;
HERMAN, PG ;
SWENSSON, RG .
RADIOLOGY, 1978, 127 (03) :589-594
[10]   SEARCHING FOR LUNG NODULES - A COMPARISON OF HUMAN-PERFORMANCE WITH RANDOM AND SYSTEMATIC SCANNING MODELS [J].
KUNDEL, HL ;
NODINE, CF ;
THICKMAN, D ;
TOTO, L .
INVESTIGATIVE RADIOLOGY, 1987, 22 (05) :417-422