REDUCTION OF AIR POLLUTANT CONCENTRATIONS IN AN INDOOR ICE-SKATING RINK

被引:8
作者
LEE, KY
YANAGISAWA, Y
SPENGLER, JD
机构
[1] Harvard University School of Public Health, Department of Environmental Health, Boston
关键词
D O I
10.1016/0160-4120(94)90136-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
High carbon monoxide and nitrogen dioxide concentrations were measured in an indoor ice-skating rink with fuel-powered ice-resurfacing equipment. In 22% to 33% of the measurements over 90-min segments, CO concentrations exceeded 20 muL/L as a 90-min average in the absence of rink ventilation. Average NO2 concentrations over 14 h were higher than 600 nL/L. Reduction of air pollutant concentrations in the ice-skating rink is necessary to prevent air-pollutant-exposure-related health incidents. Various methods for reducing air pollutants in an ice-skating rink were evaluated by simultaneously measuring CO and NO2 concentrations. Single pollution reduction attempts, such as extension of the exhaust pipe, reduction in the number of resurfacer operations, or use of an air recirculation system, did not significantly reduce air pollutant concentrations in the rink. Full operation of the mechanical ventilation system combined with reduced resurfacer operation was required to keep the air pollutant levels in the skating rink below the recommended guidelines. This investigation showed that management of clean air quality in an ice-skating rink is practically difficult as long as fuel-powered resurfacing equipment is used.
引用
收藏
页码:191 / 199
页数:9
相关论文
共 17 条
[1]  
Anderson, Problems created from ice arenas by engine exhaust, Am. Ind. Hyg. Assoc. J., 32, pp. 790-801, (1971)
[2]  
Coueffin, Carbon monoxide: a problem in enclosed ice arenas, Environ. Health Rev., 25, pp. 64-66, (1981)
[3]  
Federal Register, Review of the national ambient air quality standards for carbon monoxide
[4]  
final rule, Federal Register, 50, pp. 37484-37501, (1985)
[5]  
Forbes, Sargent, Roughton, The rate of carbon monoxide uptake by normal men, Am. J. Physiol., 143, pp. 594-608, (1945)
[6]  
Hedberg, Hedberg, Iber, White, Osterholm, Jones, Flink, MacDonald, An outbreak of nitrogen dioxide-induced respiratory illness among ice hockey players, J. Am. Med. Assoc., 26, 221, pp. 3014-3017, (1989)
[7]  
Johnson, Moran, Paine, Anderson, Breysse, Abatement of toxic levels of carbon monoxide in Seattle ice-skating rinks, Am. J. Public Health, 65, pp. 1087-1090, (1975)
[8]  
Kwok, Evaluation and control of carbon monoxide exposure in indoor skating arenas, Can. J. Public Health, 74, pp. 261-265, (1983)
[9]  
Lee, Yanagisawa, Nishinuma, Spengler, Billick, A passive sampler for measuring carbon monoxide using solid adsorbant, Environ. Sci. Technol., 26, pp. 697-702, (1992)
[10]  
Levesque, Dewailly, Lavoie, Prud'Homme, Allaire, Carbon monoxide in indoor ice skating rinks: evaluation of absorption by adult hockey players, Am. J. Public Health, 80, pp. 594-598, (1990)