PERFUSION IMAGING OF THE BRAIN BY B-MODE ULTRASONOGRAPHY - AN EXPERIMENTAL-STUDY IN RABBITS

被引:12
作者
ITOH, T
MATSUMOTO, M
UCHIMOTO, R
TAKAHASHI, N
NIWA, K
HANDA, N
TSUKAMOTO, Y
MIYAZAWA, T
KAMADA, T
机构
[1] OSAKA UNIV,SCH MED,DEPT PATHOL,SUITA,OSAKA 565,JAPAN
[2] NIHON SCHERING KK,RES DEPT,OSAKA,JAPAN
关键词
CONTRAST MEDIA; PERFUSION; ULTRASONICS; RABBITS;
D O I
10.1161/01.STR.26.12.2353
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose The purpose of this study was to assess the ultrasonic imaging of normal rabbit brain by using echocontrast enhancer to identify the brain tissue perfusion. Methods A solution of SH/TA-508 (containing microbubbles of mean size 2 to 4 mu m; n=4) was used for contrast enhancement of rabbit brain tissue and was administered through the left internal carotid artery. Contrast enhancement in the ipsilateral parietal area was examined by placing a 7.5-MHZ transducer on the dura after a craniectomy. Throughout the experiment, we measured parameters including arterial blood pressure, arterial blood gases, and serum glucose and hematocrit levels. We investigated whether the administration of an echocontrast enhancer would be safe: for the brain tissue (n=4). Results After injection of 100 mg/mL SH/TA-508, contrast enhancement was clearly observed within approximately 1 second in the left hemisphere (especially in the left cerebral cortex) in all animals and disappeared within 3 seconds after the end of injection. All physiological parameters remained within the normal range throughout the experiment. No focal abnormalities were observed on hematoxylin-eosin staining of the brain tissue. Conclusions Contrast enhancement was observed in the ipsilateral hemisphere with the administration of SH/TA-508. Contrast enhancement on B-mode brain imaging would be useful for real-time identification of brain tissue perfusion and should become a promising method for bedside clinical assess ment of brain tissue perfusion.
引用
收藏
页码:2353 / 2356
页数:4
相关论文
共 17 条
[1]   CONTRAST-ENHANCED TRANSCRANIAL COLOR-CODED REAL-TIME SONOGRAPHY - RESULTS OF A PHASE-2 STUDY [J].
BOGDAHN, U ;
BECKER, G ;
SCHLIEF, R ;
REDDIG, J ;
HASSEL, W .
STROKE, 1993, 24 (05) :676-684
[2]   INTRA-OPERATIVE USE OF REAL-TIME ULTRASONOGRAPHY IN NEUROSURGERY [J].
CHANDLER, WF ;
KNAKE, JE ;
MCGILLICUDDY, JE ;
LILLEHEI, KO ;
SILVER, TM .
JOURNAL OF NEUROSURGERY, 1982, 57 (02) :157-163
[3]   RECOMBINANT TISSUE PLASMINOGEN-ACTIVATOR IN ACUTE THROMBOTIC AND EMBOLIC STROKE [J].
DELZOPPO, GJ ;
POECK, K ;
PESSIN, MS ;
WOLPERT, SM ;
FURLAN, AJ ;
FERBERT, A ;
ALBERTS, MJ ;
ZIVIN, JA ;
WECHSLER, L ;
BUSSE, O ;
GREENLEE, R ;
BRASS, L ;
MOHR, JP ;
FELDMANN, E ;
HACKE, W ;
KASE, CS ;
BILLER, J ;
GRESS, D ;
OTIS, SM .
ANNALS OF NEUROLOGY, 1992, 32 (01) :78-86
[4]   REAL-TIME ULTRASONOGRAPHY - ITS USE IN THE EVALUATION OF NEONATAL INTRA-CRANICAL HEMORRHAGE AND POSTHEMORRHAGIC HYDROCEPHALUS [J].
DONN, SM ;
GOLDSTEIN, GW ;
SILVER, TM .
AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1981, 135 (04) :319-321
[5]   PILOT RANDOMIZED TRIAL OF TISSUE-PLASMINOGEN ACTIVATOR IN ACUTE ISCHEMIC STROKE [J].
HALEY, EC ;
BROTT, TG ;
SHEPPARD, GL ;
BARSAN, W ;
BRODERICK, J ;
MARLER, JR ;
KONGABLE, GL ;
SPILKER, J ;
MASSEY, S ;
HANSEN, CA ;
TORNER, JC .
STROKE, 1993, 24 (07) :1000-1004
[6]   A COMPARISON OF INTRAARTERIAL AND INTRAVENOUS TISSUE-TYPE PLASMINOGEN-ACTIVATOR ON AUTOLOGOUS ARTERIAL EMBOLI IN THE CEREBRAL-CIRCULATION OF RABBITS [J].
HAMILTON, MG ;
LEE, JS ;
CUMMINGS, PJ ;
ZABRAMSKI, JM .
STROKE, 1994, 25 (03) :651-655
[7]  
HUBER P, 1982, CEREBRAL ANGIOGRAPHY, P243
[8]   LACK OF MYOCARDIAL PERFUSION IMMEDIATELY AFTER SUCCESSFUL THROMBOLYSIS - A PREDICTOR OF POOR RECOVERY OF LEFT-VENTRICULAR FUNCTION IN ANTERIOR MYOCARDIAL-INFARCTION [J].
ITO, H ;
TOMOOKA, T ;
SAKAI, N ;
YU, H ;
HIGASHINO, Y ;
FUJII, K ;
MASUYAMA, T ;
KITABATAKE, A ;
MINAMINO, T .
CIRCULATION, 1992, 85 (05) :1699-1705
[9]   THE BEHAVIOR OF SONICATED ALBUMIN MICROBUBBLES WITHIN THE MICROCIRCULATION - A BASIS FOR THEIR USE DURING MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY [J].
KELLER, MW ;
SEGAL, SS ;
KAUL, S ;
DULING, B .
CIRCULATION RESEARCH, 1989, 65 (02) :458-467
[10]  
MAJNO G, 1967, LANCET, V9, P569