The evaluation of the ampere-hour capacity of a lead-acid battery using the technique of mathematical modeling is presented in this paper. The battery model was used to simulated a battery cycle at different temperatures, at different rates of charge and discharge and at different end voltages to determine how the battery parameter of ampere-hour capacity was affected. The parameter obtained from the model simulation was compared with experimental result for verification.