EFFECTS OF ACCELERATION ON THE ACCURACY OF MR PHASE-VELOCITY MEASUREMENTS

被引:47
作者
OSHINSKI, JN [1 ]
KU, DN [1 ]
BOHNING, DE [1 ]
PETTIGREW, RI [1 ]
机构
[1] GEORGIA INST TECHNOL,GEORGE W WOODRUFF SCH MECH ENGN,277 FERST DR,ATLANTA,GA 30332
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1992年 / 2卷 / 06期
关键词
BLOOD; FLOW DYNAMICS; LOOD VESSELS; STENOSIS OR OBSTRUCTION; GRADIENT WAVE-FORMS; PHANTOMS; VASCULAR STUDIES;
D O I
10.1002/jmri.1880020610
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Acceleration in blood flow can affect the accuracy of phase velocity measurements. Convective acceleration is due to changes in flow geometry and is independent of the time-varying acceleration caused by flow pulsatility. To analyze the effects of convective acceleration on flow velocity measurements, phase velocity measurements were obtained in steady laminar flow in the convergent segment of a 90%, hourglass-shaped stenosis phantom at a Reynolds number of 1,500. Measurements at the stenosis indicated that convective acceleration caused the measured values of average cross-sectional velocity to deviate as much as 37% from the theoretical values. The magnitude of the error could be accounted for by including the convective acceleration term in the phase shift equation. Convective acceleration effects should not be ignored in flow velocity measurements through stenoses. even when time-dependent acceleration due to flow pulsatility can be neglected.
引用
收藏
页码:665 / 670
页数:6
相关论文
共 21 条
[1]  
Podolak MJ, Hedlund LW, Evans AJ, Herfkens RJ, Evaluation of flow through simulated vascular stenosis with gradient echo magnetic resonance imaging, Invest Radiol, 23, pp. 184-189, (1989)
[2]  
Evans AJ, Blinder RA, Herfkens RJ, Et al., Effects of turbulence on signal intensity in gradient images, Invest Radiol, 23, pp. 149-163, (1984)
[3]  
Krug B, Kugel H, Friedmann G, Et al., MR imaging of poststenotic flow phenomena: experimental studies, JMRI, 1, pp. 585-591, (1991)
[4]  
Ku DN, Pettigrew RI, Markou C, Biancheri C, Fluid mechanics of signal loss in MR images (abstr), Book of abstracts: Society of Magnetic Resonance in Medicine 1990, (1990)
[5]  
Pettigrew RI, Daniels W, Galloway JR, Quantitative phase flow MR imaging in dogs by using standard sequences: comparison with in vivo flow meter measurements, AJR, 148, pp. 411-414, (1987)
[6]  
Firmin DN, Nayler GL, Klipstein RH, Underwood SR, Rees RSO, Longmore DB, In vivo validation of MR velocity imaging, J Comput Assist Tomogr, 11, pp. 751-756, (1987)
[7]  
Meter D, Mater S, Bosiger P, Quantitative flow measurements on phantoms and on blood vessels with MR, Magnetic Resonance in Medicine, 8, pp. 25-34, (1988)
[8]  
Vieli A, Moser S, Maier D, Bosiger P, Velocity profiles in the human abdominal aorta: a comparison between ultrasound and magnetic resonance data, Ultrasound Med, 13, pp. 113-119, (1989)
[9]  
Firmin DN, Nayler GL, Kilner PJ, Longmore DB, The application of phase shifts in NMR for flow measurement, Magn ResonMed, 14, pp. 230-241, (1990)
[10]  
Poiseau E, (1989)