LONG-TERM RESULTS OF INFLATABLE MAMMARY IMPLANTS

被引:31
作者
WORSEG, A
KUZBARI, R
TAIRYCH, G
KORAK, K
HOLLE, J
机构
[1] Department of Plastic and Reconstructive Surgery, Wilhelminen Hospital, Vienna
来源
BRITISH JOURNAL OF PLASTIC SURGERY | 1995年 / 48卷 / 04期
关键词
D O I
10.1016/0007-1226(95)90000-4
中图分类号
R61 [外科手术学];
学科分类号
摘要
In this retrospective study, the long term results of 167 inflatable mammary implants in 77 patients who underwent either breast reconstruction or augmentation between 1972 and 1990 were evaluated. All inflatable implants were manufactured by Heyer-Schulte/Mentor company, and were equipped with a posterior leaf valve (style 1800). The mean follow-up was 9 years (SD=4.3). Complete deflation was found in 23.9% of the implants (22.2% deflation rate from 1972 to 1984 and 25.5% from 1985 to 1992); The incidence of this complication was significantly higher in patients who underwent previous open (p=0.012) or closed (p=0.038) capsulotomy. Severe contracture of the implant fibrous capsule (BAC 3 and 4) was found in 37.6% of the patients. Its incidence increased significantly when the postoperative blood loss (assessed by the volume of blood collected by suction drainage) exceeded 250 cc (p=0.025). Neither the site of the implant (submuscular/subglandular) nor the indication for surgery (reconstruction/augmentation) influenced the rate of severe capsular contracture significantly in this retrospective study.
引用
收藏
页码:183 / 188
页数:6
相关论文
共 26 条
[1]  
ASPLUND O, 1984, PLAST RECONSTR SURG, V73, P270, DOI 10.1097/00006534-198402000-00022
[2]   POSITIVE IDENTIFICATION OF SILICONE IN HUMAN MAMMARY CAPSULAR TISSUE [J].
BAKER, JL ;
LEVIER, RR ;
SPIELVOGEL, DE .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1982, 69 (01) :56-60
[3]   BLEEDING OF SILICONE FROM BAG-GEL BREAST IMPLANTS, AND ITS CLINICAL RELATION TO FIBROUS CAPSULE REACTION [J].
BARKER, DE ;
RETSKY, MI ;
SCHULTZ, S .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1978, 61 (06) :836-841
[4]   EXUDATION OF SILICONE THROUGH THE ENVELOPE OF GEL-FILLED BREAST PROSTHESES - INVITRO STUDY [J].
BERGMAN, RB ;
VANDERENDE, AE .
BRITISH JOURNAL OF PLASTIC SURGERY, 1979, 32 (01) :31-34
[5]   CLINICAL-EXPERIENCE WITH HEYER-SCHULTE INFLATABLE IMPLANTS IN BREAST AUGMENTATION [J].
CAPOZZI, A .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1986, 77 (05) :772-778
[6]   DELAYED EXTRUSION OF INFLATABLE BREAST PROSTHESES [J].
DERMAN, GH ;
ARGENTA, LC ;
GRABB, WC .
ANNALS OF PLASTIC SURGERY, 1983, 10 (02) :154-158
[7]   HISTOLOGICAL INVESTIGATION OF ETIOLOGY OF CAPSULE CONTRACTURE FOLLOWING AUGMENTATION MAMMAPLASTY [J].
DOMANSKIS, EJ ;
OWSLEY, JQ .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1976, 58 (06) :689-693
[8]   RUPTURE OF INFLATED BREAST IMPLANTS IN CLOSE COMPRESSION CAPSULOTOMY [J].
FELIBERTI, MC ;
ARRILLAGA, A ;
COLON, GA .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1977, 59 (06) :848-848
[9]   RESULTS OF SUBGLANDULAR BREAST AUGMENTATION USING A NEW CLASSIFICATION METHOD - 18-YEAR FOLLOW-UP [J].
GYLBERT, L ;
ASPLUND, O ;
JURELL, G ;
OLENIUS, M .
SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1989, 23 (02) :133-136
[10]   CONSTANT COMPRESSION CALIPER FOR OBJECTIVE MEASUREMENT OF BREAST CAPSULAR CONTRACTURE [J].
GYLBERT, L ;
BERGGREN, A .
SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1989, 23 (02) :137-142