CALCULATION OF UMP IN INDUCTION-MOTORS WITH SERIES OR PARALLEL WINDING CONNECTIONS

被引:68
作者
DORRELL, DG
SMITH, AC
机构
[1] Dept. of Engineering, Cambridge University, Cambridge
关键词
INDUCTION MOTORS; STATOR WINDINGS; PARALLEL-PATHS; PERFORMANCE; UNBALANCED MAGNETIC PULL;
D O I
10.1109/60.300144
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a general analytical method for determining the UMP produced in three-phase induction motors with an eccentric rotor. The model uses the conformal transformation technique coupled to a winding impedance approach that is capable of accomodating any stator winding connection. The paper examines the influence of using parallel stator winding paths as a means of reducing the resultant UMP (static and pulsating). The results clearly demonstrate the significant reduction of static UMP of a typical stator winding with parallel paths together with the unbalanced winding currents that are produced.
引用
收藏
页码:304 / 310
页数:7
相关论文
共 14 条
[1]  
Belmans R., 1987, P I ELECT ENG B, V134, P101
[2]   IDENTIFICATION OF PRINCIPAL FACTORS CAUSING UNBALANCED MAGNETIC PULL IN CAGE INDUCTION-MOTORS [J].
BINNS, KJ ;
DYE, M .
PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1973, 120 (03) :349-354
[3]   UNBALANCED MAGNETIC PULL IN A 6-POLE INDUCTION MOTOR [J].
BRADFORD, M .
PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1968, 115 (11) :1619-&
[4]  
BRADFORD M, 1968, 5216 EL RES ASS REP
[5]   EFFECTS OF ROTOR ECCENTRICITY ON ACOUSTIC NOISE FROM INDUCTION MACHINES [J].
ELLISON, AJ ;
YANG, SJ .
PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1971, 118 (01) :174-&
[6]   RUNNING INSTABILITY OF CAGE INDUCTION-MOTORS CAUSED BY HARMONIC FIELDS DUE TO ECCENTRICITY .1. ELECTROMAGNETIC SPRING CONSTANT AND ELECTROMAGNETIC DAMPING COEFFICIENT [J].
FRUCHTENICHT, J ;
JORDAN, H ;
SEINSCH, HO .
ARCHIV FUR ELEKTROTECHNIK, 1982, 65 (4-5) :271-281
[7]  
KOVACS KP, 1977, T IEEE PAS, V96, P1105
[8]  
KRONDL M, 1956, B ASS SUISSE ELEC, V47, P581
[9]  
Swann S.A., 1963, P I ELECTR ENG, V110, P903
[10]  
VONKAEHNE P, 1963, ZT142 EL RES ASS REP