INTRAVENTRICULAR ELECTROGRAM ANALYSIS FOR VENTRICULAR-TACHYCARDIA DETECTION - STATISTICAL VALIDATION

被引:17
作者
THRONE, RD
JENKINS, JM
DICARLO, LA
机构
[1] CATHERINE MCAULEY HLTH CTR,DEPT ELECT ENGN & COMP SCI,MED COMP LAB,REICHERT HLTH BLDG R-3003,ANN ARBOR,MI 48106
[2] CATHERINE MCAULEY HLTH CTR,ST JOSEPH MERCY HOSP,CARDIAC ELECTROPHYS LAB,ANN ARBOR,MI 48106
[3] UNIV MICHIGAN,SCH MED,ANN ARBOR,MI 48104
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1990年 / 13卷 / 12期
关键词
STATISTICAL VALIDATION; CORRELATION WAVE-FORM ANALYSIS; AREA OF DIFFERENCE; NONPARAMETRIC TOLERANCE INTERVALS; VENTRICULAR TACHYCARDIA DETECTION;
D O I
10.1111/j.1540-8159.1990.tb06860.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Time-domain analysis of intraventricular electrogram morphology during ventricular tachycardia (VT) and sinus rhythm or atrial fibrillation (SR/AF has been proposed as a method for increasing the specificity of pathological tachycardia detection by antitachycardia devices. However, few studies have validated the use of such analysis with statistical methods. When statistical methods have been utilized, it has been assumed that the distribution of the values derived from analysis of the intracardiac electrograms have had a normal (gaussin) distribution. In this study, we sought to determine whether: (1) the distribution of values derived from analysis of intracardiac electrogarm during SR/AF and VT is gaussian or nongaussian; and (2) the discrimination of monomorphic VT from SR/AF using SR/AF templates can be validated statistically. Two previously proposed time-domain methods-correlation waveform analysis (CWA) and area of difference (AD)- were selected for evaluation of 29 patients with 33 distinct, sustained monomorphic VTs. An initial SR/AF template was used to analyze subsequent SR/AF and VT passages with a minimum of 50 consecutive depolarizations using a "best-fit" alignment. The values derived from each analysis were examined subsequently for skewness (asymmetry) and kurtosis (shape) using two-tailed tests (P < 0.02). For passages of SR/AF, a normal (gaussian) distribution was present in only 24% (CWA), and 45% (AD); for passages of VT, normal distribution was present in only 58% for both CWA and AD. Using appropriate statistical testing with nonparametric tolerance intervals, CWA and AD discriminated VT from SR/AF in 29 out of 33 (88%), and 30 out of 33 (91%) instances, respectively, with 95% confidence. Thus, the assumption of a gaussian distribution for values derived from time-domain analysis of intraventricular electrograms for VT detection is not uniformly valid. Both CWA, which is independent of both baseline and amplitude fluctuations, and AD, which is not independent of these fluctuations, have similar performance when validated with appropriate statistical methods.
引用
收藏
页码:1596 / 1601
页数:6
相关论文
共 28 条
  • [1] DETECTION OF PATHOLOGICAL TACHYCARDIA BY ANALYSIS OF ELECTROGRAM MORPHOLOGY
    DAVIES, DW
    WAINWRIGHT, RJ
    TOOLEY, MA
    LLOYD, D
    NATHAN, AW
    SPURRELL, RAJ
    CAMM, AJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (02): : 200 - 208
  • [2] CLINICAL-EXPERIENCE, COMPLICATIONS, AND SURVIVAL IN 70 PATIENTS WITH THE AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    ECHT, DS
    ARMSTRONG, K
    SCHMIDT, P
    OYER, PE
    STINSON, EB
    WINKLE, RA
    [J]. CIRCULATION, 1985, 71 (02) : 289 - 296
  • [3] MAXIMAL RATE OF TACHYCARDIA DEVELOPMENT - SINUS TACHYCARDIA WITH SUDDEN EXERCISE VS SPONTANEOUS VENTRICULAR-TACHYCARDIA
    FISHER, JD
    GOLDSTEIN, M
    OSTROW, E
    MATOS, JA
    KIM, SG
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1983, 6 (02): : 221 - 228
  • [4] FROMER M, 1987, PACE, V10, P451
  • [5] AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR - PATIENT SURVIVAL, BATTERY LONGEVITY AND SHOCK DELIVERY ANALYSIS
    GABRY, MD
    BRODMAN, R
    JOHNSTON, D
    FRAME, R
    KIM, SG
    WASPE, LE
    FISHER, JD
    FURMAN, S
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (06) : 1349 - 1356
  • [6] Geary RC, 1936, BIOMETRIKA, V28, P295, DOI 10.2307/2333953
  • [7] GIEBEL A, 1988, AM HEART J, P588
  • [8] IDENTIFICATION OF VENTRICULAR-TACHYCARDIA WITH USE OF THE MORPHOLOGY OF THE ENDOCARDIAL ELECTROGRAM
    LANGBERG, JJ
    GIBB, WJ
    AUSLANDER, DM
    GRIFFIN, JC
    [J]. CIRCULATION, 1988, 77 (06) : 1363 - 1369
  • [9] IDENTIFICATION OF VENTRICULAR-TACHYCARDIA USING INTRACAVITARY VENTRICULAR ELECTROGRAMS - ANALYSIS OF TIME AND FREQUENCY-DOMAIN PATTERNS
    LIN, DP
    DICARLO, LA
    JENKINS, JM
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11): : 1592 - 1606
  • [10] MANZ AS, 1986, AM J CARDIOL, V7, P343