MR CHARACTERIZATION OF BLOOD-FLOW IN NATIVE AND GRAFTED INTERNAL MAMMARY ARTERIES

被引:36
作者
DEBATIN, JF
STRONG, JA
SOSTMAN, HD
NEGROVILAR, R
PAINE, SS
DOUGLAS, JM
PELC, NJ
机构
[1] Department of Radiology, Stanford University Medical Center, Stanford, California, 94305, Rm HI 307
[2] Departments of Radiology, Duke University Medical Center., Durham, North Carolina
[3] Duke University Medical Center., Durham, North Carolina
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1993年 / 3卷 / 03期
关键词
ARTERIES; GRAFTS AND PROSTHESES; INTERNAL MAMMARY; CINE STUDIES; CORONARY VESSELS; STENOSIS OR OBSTRUCTION; SURGERY; FLOW QUANTIFICATION; GRAFTS; PHASE IMAGING; VASCULAR STUDIES; VELOCITY STUDIES;
D O I
10.1002/jmri.1880030303
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In the postoperative patient with anginal symptoms, differentiation between bypass graft compromise and nonischemic causes has until now been accomplished only by means of x-ray angiography. A noninvasive test is clearly desirable. The authors used a cine phase-contrast (PC) magnetic resonance (MR) imaging technique to characterize blood flow in native and grafted internal mammary arteries (IMAs). Ten volunteers and 15 patients who had recently undergone IMA coronary artery bypass grafting were imaged. Cine PC MR imaging was performed in the transaxial plane at the level of the pulmonary artery bifurcation. Flow in both IMAs was quantified and expressed as a percentage of cardiac output measured in the ascending aorta. In the 15 patients, flow analysis was performed in both the native and grafted IMAs. In the volunteers, IMA blood flow ranged from 2. 1 % to 4.3 % of cardiac output on the left (mean, 3.5%) and 2. 1 % to 5. 1 % (mean, 3.5%) on the right. There was considerable intersubject variability, with coefficients of variation of 10.7 % for the left and 12.3 % for the right IMA. Intrasubject variability was limited, with estimated common standard deviations of 0.45 % of cardiac output (range, 0.2%-1.1 %) for the left and 0.39% (range, 0.1%-0.6%) for the right IMA. Flow in grafted IMAs was identified in 13 of 15 patients. In one of two patients without demonstrable IMA graft flow, cardiac catheterization confirmed lack of flow. IMA graft flow varied from 28 to 164 mL/min (mean, 80.3 ml/min). This study shows the feasibility of using cine PC MR imaging as a quantitative method of evaluating blood flow in IMA coronary artery bypass grafts.
引用
收藏
页码:443 / 450
页数:8
相关论文
共 32 条
  • [1] Zeff RH, Kongtahworn C, Iannone LA, Et al., Internal mammary artery versus saphenous vein graft to the left anterior descending coronary artery: prospective randomized study with 10‐year follow‐up, Ann Thorac Surg, 45, pp. 533-536, (1988)
  • [2] Cameron A, Davis KB, Green GE, Myers WO, Pettinger M, Clinical implications of internal mammary artery bypass grafts: the coronary artery surgery study experience, Circulation, 77, pp. 815-819, (1988)
  • [3] Loop FD, Lytle BW, Cosgrove DM, Et al., Influence of the internal‐mammary artery graft on 10‐year survival and other cardiac events, N Engl J Med, 314, pp. 1-6, (1986)
  • [4] Cameron A, Kemp HG, Green GE, Bypass surgery with the internal mammary artery graft: 15 year follow‐up, Circulation, 74, (1986)
  • [5] Bandyk DF, Galbraith TA, Haasler GB, Almassi GH, Blood flow velocity of internal mammary artery and saphenous vein grafts to the coronary arteries, J Surg Res, 44, pp. 342-351, (1988)
  • [6] Bauer EP, Bino MC, von Segesser LK, Laske A., Turina MI, Internal mammary artery anomalies, Thorac Cardiovasc Surg, 38, pp. 312-315, (1990)
  • [7] Oberman A, Kouchoukos NT, Harrell RR, Holt JH, Russell RO, Rackley CE, Surgical versus medical treatment in disease of the left main coronary artery, Lancet, 2, pp. 591-594, (1976)
  • [8] White RD, Pflugfelder PW, Lipton MJ, Higgins CB, Coronary artery bypass grafts: evaluation of patency with cine MR imaging, AJR, 150, pp. 1271-1274, (1988)
  • [9] Godwin JD, Califf RM, Korobkin M, Moore AV, Breiman RS, Kong Y, Clinical value of coronary bypass graft evaluation with CT, AJR, 140, pp. 649-655, (1983)
  • [10] Guthaner DF, Wexler L, Bradley B, Digital subtraction angiography of coronary grafts: optimization of technique, AJR, 145, pp. 1185-1190, (1985)