PNEUMATIC HYDROGEN PELLET INJECTION SYSTEM FOR THE ISX TOKAMAK

被引:45
作者
MILORA, SL
FOSTER, CA
机构
[1] Fusion Energy Division, Oak Ridge National Laboratory, Oak Ridge
关键词
D O I
10.1063/1.1135856
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe the design and operation of the solid hydrogen pellet injection system used in plasma refueling experiments on the ISX tokamak. The gun-type injector operates on the principle of gas dynamic acceleration of cold pellets confined laterally in a tube. The device is cooled by flowing liquid helium refrigerant, and pellets are formed in situ. Room temperature helium gas at moderate pressure is used as the propellant. The prototype device injected single hydrogen pellets into the tokamak discharge at a nominal 330 m/s. The tokamak plasma fuel content was observed to increase by (0.5-1.2) ×10 19 particles subsequent to pellet injection. A simple modification to the existing design has extended the performance to 1000 m/s. At higher propellant operating pressures (28 bars), the muzzle velocity is 20% less than predicted by an idealized constant area expansion process.
引用
收藏
页码:482 / 487
页数:6
相关论文
共 8 条
[1]  
AMENDA W, 1978, P FUSION FUELING WOR
[2]   APPARATUS FOR PRODUCING UNIFORM SOLID SPHERES OF HYDROGEN [J].
FOSTER, CA ;
KIM, K ;
TURNBULL, RJ ;
HENDRICKS, CD .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1977, 48 (06) :625-631
[3]   SOLID HYDROGEN PELLET INJECTION INTO ORMAK TOKAMAK [J].
FOSTER, CA ;
COLCHIN, RJ ;
MILORA, SL ;
KIM, K ;
TURNBULL, RJ .
NUCLEAR FUSION, 1977, 17 (05) :1067-1075
[4]  
Landau L.D., 2013, Course of theoretical physics
[5]  
MILORA SL, 1978, ORNLTM6496
[6]  
MILORA SL, UNPUBLISHED
[7]  
MILORA SL, 1977, ORNLTM5776
[8]  
STETSENKO YE, 1972, SOV PHYS SOLID STATE, V14, P1