EFFECT OF HOMONUCLEAR-J MODULATION ON F-19 SPIN-ECHO IMAGES

被引:10
作者
BABCOCK, EE
MASON, RP
ANTICH, PP
机构
[1] Advanced Radiological Sciences, Department of Radiology, University of Texas Southwestern Medical Center, Dallas, Texas
关键词
D O I
10.1002/mrm.1910170121
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The effect of homonuclear J modulation on 19F spin‐echo images is evidenced by a substantial reduction in signal when the echo time, TE, approaches 1 /2J, with a subsequent increase in signal at longer TEs. Suppression of the J‐modulation effect is demonstrated using chemical Shift‐Selective 180° refocusing pulses. © 1991 Academic Press, Inc. Copyright © 1991 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:179 / 188
页数:10
相关论文
共 31 条
[1]   P-31 NMR MEASUREMENTS OF T2 RELAXATION-TIMES OF ATP WITH SURFACE COILS - SUPPRESSION OF J MODULATION [J].
ALBRAND, JP ;
FORAY, MF ;
DECORPS, M .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) :941-945
[2]   F-19 MAGNETIC-RESONANCE IMAGING AND SPECTROSCOPY OF A FLUORINATED NEUROLEPTIC LIGAND - INVIVO AND INVITRO STUDIES [J].
ARNDT, DC ;
RATNER, AV ;
FAULL, KF ;
BARCHAS, JD ;
YOUNG, SW .
PSYCHIATRY RESEARCH, 1988, 25 (01) :73-79
[3]   CHEMICAL-SHIFT-SENSITIVE NMR IMAGING USING SPECTRUM SIMPLIFICATION BY TAILORED EXCITATION [J].
BORNERT, P ;
DREHER, W ;
GOSSLER, A ;
KLEE, G ;
PETER, R ;
SCHNEIDER, W .
JOURNAL OF MAGNETIC RESONANCE, 1989, 81 (01) :167-172
[4]   DECONVOLUTION OF CHEMICAL-SHIFT SPECTRA IN TWO-DIMENSIONAL OR 3-DIMENSIONAL [F-19] MR IMAGING [J].
BUSSE, LJ ;
PRATT, RG ;
THOMAS, SR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (05) :824-835
[5]  
CHEW W M, 1987, Magnetic Resonance Imaging, V5, P51, DOI 10.1016/0730-725X(87)90483-8
[7]   F-19 IMAGING OF CEREBRAL BLOOD OXYGENATION IN EXPERIMENTAL MIDDLE CEREBRAL-ARTERY OCCLUSION - PRELIMINARY-RESULTS [J].
EIDELBERG, D ;
JOHNSON, G ;
TOFTS, PS ;
DOBBIN, J ;
CROCKARD, HA ;
PLUMMER, D .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (02) :276-281
[8]   INVIVO MEASUREMENTS OF VASCULAR OXYGEN-TENSION IN TUMORS USING MRI OF A FLUORINATED BLOOD SUBSTITUTE [J].
FISHMAN, JE ;
JOSEPH, PM ;
CARVLIN, MJ ;
SAADIELMANDJRA, M ;
MUKHERJI, B ;
SLOVITER, HA .
INVESTIGATIVE RADIOLOGY, 1989, 24 (01) :65-71
[9]   RAPID F-19 MAGNETIC-RESONANCE IMAGING OF PERFLUOROOCTYL BROMIDE INVIVO [J].
FREEMAN, DM ;
MULLER, HH ;
HURD, RE ;
YOUNG, SW .
MAGNETIC RESONANCE IMAGING, 1988, 6 (01) :61-64
[10]   SPIN ECHO MEASUREMENTS OF NUCLEAR SPIN COUPLING IN MOLECULES [J].
HAHN, EL ;
MAXWELL, DE .
PHYSICAL REVIEW, 1952, 88 (05) :1070-1084