CURRENT SHEET APPLICATOR ARRAYS FOR SUPERFICIAL HYPERTHERMIA OF CHESTWALL LESIONS

被引:40
作者
GOPAL, MK
HAND, JW
LUMORI, MLD
ALKHAIRI, S
PAULSEN, KD
CETAS, TC
机构
[1] HAMMERSMITH HOSP,MRC,CYCLOTRON UNIT,LONDON W12 0HS,ENGLAND
[2] UNIV ARIZONA,DEPT ELECT & COMP ENGN,TUCSON,AZ 85721
关键词
HYPERTHERMIA; CURRENT SHEET APPLICATOR; MICROWAVE ARRAYS;
D O I
10.3109/02656739209021778
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The current sheet applicator is an electromagnetic heating device whose size be chosen virtually independent of frequency even though practical limitations may restrict it to VHF and UHF bands. In this paper we investigate absorbed power distributions in muscle tissue from current sheet applicators when used as elements of a planar array intended for superficial hyperthermic treatment of tumours. Advantages offered by current sheet applicators for tissue heating include compact size, a linear polarization of the induced electric field and relatively large heating area. It is shown that the effective field produced by a pair of these elements is continuous regardless of whether the common edges of the elements are perpendicular or parallel to the direction of impressed current. The feasibility of customizing the shape and size of the field is also illustrated. The absorbed power distribution patterns due to a coherently driven array operating around 434 MHz is relatively insensitive to phase variations ot about 20-degrees but is sensitive to relative power level variations as low as 10%. Mutual coupling between array elements may be reduced to acceptable levels by incorporating suitable spacing between them. It is also demonstrated that there is good agreement between measurements of absorbed power distributions and predictions using the Gaussian beam model.
引用
收藏
页码:227 / 240
页数:14
相关论文
共 23 条
[1]   A HYPERTHERMIA SYSTEM USING A NEW TYPE OF INDUCTIVE APPLICATOR [J].
ANDERSEN, JB ;
BAUN, A ;
HARMARK, K ;
HEINZL, L ;
RASKMARK, P ;
OVERGAARD, J .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (01) :21-27
[2]   INVIVO PROBE MEASUREMENT TECHNIQUE FOR DETERMINING DIELECTRIC-PROPERTIES AT VHF THROUGH MICROWAVE-FREQUENCIES [J].
BURDETTE, EC ;
CAIN, FL ;
SEALS, J .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1980, 28 (04) :414-427
[3]  
CHEEVER E, 1986, IEEE T MICROWAVE THE, V35, P865
[4]   LOW-FREQUENCY RF TWIN-DIPOLE APPLICATOR FOR INTERMEDIATE DEPTH HYPERTHERMIA [J].
FRANCONI, C ;
TIBERIO, CA ;
RAGANELLA, L ;
BEGNOZZI, L .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1986, 34 (05) :612-619
[5]   FOCUSED ARRAY HYPERTHERMIA APPLICATOR - THEORY AND EXPERIMENT [J].
GEE, W ;
LEE, SW ;
BONG, NK ;
CAIN, CA ;
MITTRA, R ;
MAGIN, RL .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1984, 31 (01) :38-46
[6]  
GUY AW, 1971, IEEE T MICROW THEORY, V19, P189
[7]   ABSORBED POWER DISTRIBUTIONS FROM COHERENT MICROWAVE ARRAYS FOR LOCALIZED HYPERTHERMIA [J].
HAND, JW ;
CHEETHAM, JL ;
HIND, AJ .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1986, 34 (05) :484-489
[8]   QUALITY ASSURANCE GUIDELINES FOR ESHO PROTOCOLS [J].
HAND, JW ;
LAGENDIJK, JJW ;
ANDERSEN, JB ;
BOLOMEY, JC .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1989, 5 (04) :421-428
[9]  
HAND JW, 1986, PHYS TECH, P98
[10]  
HAND JW, 1989, HYPERTHERMIC ONCOLOG, P827