INITIATION OF MULTILEAF COLLIMATOR CONFORMAL RADIATION-THERAPY

被引:50
作者
POWLIS, WD
SMITH, AR
CHENG, E
GALVIN, JM
VILLARI, F
BLOCH, P
KLIGERMAN, MM
机构
[1] Hospital of the University of Pennsylvania, Department of Radiation Oncology, Philadelphia, PA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1993年 / 25卷 / 02期
关键词
CONFORMAL RADIATION THERAPY; MULTILEAF COLLIMATOR; 3-D TREATMENT PLANNING;
D O I
10.1016/0360-3016(93)90338-V
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Clinical studies have been initiated in conformal radiotherapy using a computer controlled multileaf collimator. Quantitative dosimetry and treatment planning studies comparing field shaping by lead alloy blocks and the multileaf collimator demonstrate the clinical acceptability of the multileaf collimator. Sixteen patients with tumors in multiple sites have received some part of their treatments with both blocking systems. Studies of dosimetry and field shaping show that the multileaf collimator produces clinically acceptable blocking for most field shapes and disease sites. The 80-20% penumbra was characterized for a wide range of shaped beams. For straight edges perpendicular to the leaf travel, the penumbra of measured dose distributions from the multileaf collimator is equal to conventional divergent blocking. When the multileaf collimator leaves approach a contour at an angle, the penumbra increases. At forty-five degrees, the maximum angle of approach, the penumbra is approximately 4 mm wider than that for divergent blocks. Three-dimensional treatment planning demonstrates that equivalent dose distributions can be obtained from the two field shaping systems. The multileaf collimator can be used effectively and efficiently to treat a variety of disease sites. Its optimal utility may be in treating complex fields-five or more shaped coplanar or non-coplanar beams. It is well suited for conformal therapy applications.
引用
收藏
页码:171 / 179
页数:9
相关论文
共 17 条
[1]   3D DOSE CALCULATIONS FOR ELECTRON AND PHOTON BEAMS [J].
ALTSCHULER, MD ;
BLOCH, P ;
BUHLE, EL ;
AYYALASOMAYAJULA, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (02) :391-411
[2]   DESIGN PRINCIPLES AND CLINICAL POSSIBILITIES WITH A NEW GENERATION OF RADIATION-THERAPY EQUIPMENT - A REVIEW [J].
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (06) :403-412
[3]  
BRAHME A, 1988, STRAHLENTHER ONKOL, V164, P343
[4]   OPTIMIZATION OF STATIONARY AND MOVING BEAM RADIATION-THERAPY TECHNIQUES [J].
BRAHME, A .
RADIOTHERAPY AND ONCOLOGY, 1988, 12 (02) :129-140
[5]   A COMPUTATIONAL SOLUTION OF THE INVERSE PROBLEM IN RADIATION-THERAPY TREATMENT PLANNING [J].
CENSOR, Y ;
ALTSCHULER, MD ;
POWLIS, WD .
APPLIED MATHEMATICS AND COMPUTATION, 1988, 25 (01) :57-87
[6]   3-DIMENSIONAL PHOTON RADIOTHERAPY PLANNING FOR LARYNGEAL AND HYPOPHARYNGEAL CANCERS .2. CONFORMATION TREATMENT PLANNING USING A MULTILEAF COLLIMATOR [J].
ESIK, O ;
BURKELBACH, J ;
BOESECKE, R ;
SCHLEGEL, W ;
NEMETH, G ;
LORENZ, WJ .
RADIOTHERAPY AND ONCOLOGY, 1991, 20 (04) :238-244
[7]   THE EFFECT OF LOCAL-CONTROL ON METASTATIC DISSEMINATION IN CARCINOMA OF THE PROSTATE - LONG-TERM RESULTS IN PATIENTS TREATED WITH I-125 IMPLANTATION [J].
FUKS, Z ;
LEIBEL, SA ;
WALLNER, KE ;
BEGG, CB ;
FAIR, WR ;
ANDERSON, LL ;
HILARIS, BS ;
WHITMORE, WF .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (03) :537-547
[8]   EVALUATION OF MULTILEAF COLLIMATOR DESIGN FOR A PHOTON-BEAM [J].
GALVIN, JM ;
SMITH, AR ;
MOELLER, RD ;
GOODMAN, RL ;
POWLIS, WD ;
RUBENSTEIN, J ;
SOLIN, LJ ;
MICHAEL, B ;
NEEDHAM, M ;
HUNTZINGER, CJ ;
KLIGERMAN, MM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 23 (04) :789-801
[9]   SHAPING OF ARBITRARY DOSE DISTRIBUTIONS BY DYNAMIC MULTILEAF COLLIMATION [J].
KALLMAN, P ;
LIND, B ;
EKLOF, A ;
BRAHME, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (11) :1291-1300
[10]   OPTIMIZATION OF BEAM WEIGHTS UNDER DOSE-VOLUME RESTRICTIONS [J].
LANGER, M ;
LEONG, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (08) :1255-1260