A CONFOCAL VIDEO-RATE LASER-BEAM SCANNING REFLECTED-LIGHT MICROSCOPE WITH NO MOVING PARTS

被引:27
作者
GOLDSTEIN, SR
HUBIN, T
ROSENTHAL, S
WASHBURN, C
机构
[1] CHESAPEAKE LASER SYST INC,LANHAM,MD 20706
[2] WASHBURN LAB INC,THORNWOOD,NY 10594
[3] MICROSOL CORP,COLUMBIA,MD 21045
来源
JOURNAL OF MICROSCOPY-OXFORD | 1990年 / 157卷
关键词
acousto‐optic scanning microscope; Confocal microscope; image dissector tube;
D O I
10.1111/j.1365-2818.1990.tb02944.x
中图分类号
TH742 [显微镜];
学科分类号
摘要
A no‐moving‐parts, 30 frames/s, laser‐beam scanning confocal reflected‐light microscope has been developed. In principle, the technique can be extended to fluorescence and transmission light microscopy. Acousto‐optic beam deflectors controlled by digital electronics move a laser beam in a 512‐line interlaced 8·5 times 8·5‐mm raster. The light passes through a beam splitter, enters an inverted microscope through the side camera port, and is imaged at the object by the microscope objective. Reflected light returns through the objective, exits the camera port, is reflected off the beam splitter, and is imaged on to the photocathode of an image dissector tube (IDT). Confocality is provided by raster scanning the IDT aperture coincident with the congruent image of the laser beam incident on the object. Real‐time jitter‐free reflected light images of a variety of biological objects have been produced. Computer‐controlled alignment of the laser scan and IDT is performed in several seconds. 1990 Blackwell Science Ltd
引用
收藏
页码:29 / 38
页数:10
相关论文
共 13 条
[1]  
BOYDE A, 1982, J MICROSC, V132, P1
[2]   IMAGING MODES IN CONFOCAL SCANNING LIGHT-MICROSCOPY (CSLM) [J].
BRAKENHOFF, GJ .
JOURNAL OF MICROSCOPY, 1979, 117 (NOV) :233-242
[3]   CONFOCAL SCANNING LIGHT-MICROSCOPY WITH HIGH APERTURE IMMERSION LENSES [J].
BRAKENHOFF, GJ ;
BLOM, P ;
BARENDS, P .
JOURNAL OF MICROSCOPY-OXFORD, 1979, 117 (NOV) :219-232
[4]   SCANNING LASER MICROSCOPE FOR BIOLOGICAL INVESTIGATIONS [J].
DAVIDOVI.P ;
EGGER, MD .
APPLIED OPTICS, 1971, 10 (07) :1615-&
[5]   NEW REFLECTED-LIGHT MICROSCOPE FOR VIEWING UNSTAINED BRAIN AND GANGLION CELLS [J].
EGGER, MD ;
PETRAN, M .
SCIENCE, 1967, 157 (3786) :305-&
[6]  
GOLDSTEIN S, 1989, J MICROSC-OXFORD, V153, pRP1
[7]   TANDEM-SCANNING REFLECTED-LIGHT MICROSCOPE [J].
PETRAN, M ;
HADRAVSKY, M ;
EGGER, MD ;
GALAMBOS, R .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1968, 58 (05) :661-+
[8]   IMAGE-FORMATION IN SCANNING MICROSCOPE [J].
SHEPPARD, CJR ;
CHOUDHURY, A .
OPTICA ACTA, 1977, 24 (10) :1051-1073
[9]   OPTICAL MICROSCOPY WITH EXTENDED DEPTH OF FIELD [J].
SHEPPARD, CJR ;
HAMILTON, DK ;
COX, IJ .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1983, 387 (1792) :171-&
[10]  
VANRESANDT RWW, 1985, J MICROSC-OXFORD, V138, P29