SPECTROPHOTOMETRIC DETERMINATION OF ETHANOL IN BLOOD USING A FLOW-INJECTION SYSTEM WITH AN IMMOBILIZED ENZYME (ALCOHOL-DEHYDROGENASE) REACTOR COUPLED TO AN ONLINE DIALYZER

被引:13
作者
MAEDER, G [1 ]
VEUTHEY, JL [1 ]
PELLETIER, M [1 ]
HAERDI, W [1 ]
机构
[1] UNIV GENEVA,DEPT INORGAN ANALYT & APPL CHEM,30 QUAI ERNEST ANSERMET,CH-1211 GENEVA 4,SWITZERLAND
关键词
D O I
10.1016/S0003-2670(00)86404-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of ethanol in whole blood without pretreatment using spectrotometric detection with an immobilized enzyme reactor coupled to an on-line dialyser is described. Optimum working conditions are given. The effects of the injection volume and the flow-rate on the peak height using the dialyser were investigated. A good linear calibration graph over the ethanol concentration range 3-40 μg ml-1 was observed; these concentrations correspond to 0.3-4.0 g of ethanol per 1000 g of whole blood prior to dilution. For comparison, whole blood samples were analysed by gas chromatography with direct injection. The effect of temperature on the peak height was also studied in a system without the dialyser. © 1990.
引用
收藏
页码:115 / 119
页数:5
相关论文
共 11 条
[1]   OXIDATION OF ALCOHOLS BY YEAST ALCOHOL DEHYDROGENASE AND BY THE LIVING CELL - THE THIOL GROUPS OF THE ENZYME [J].
BARRON, ESG ;
LEVINE, S .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1952, 41 (01) :175-187
[2]   AN ENZYMATIC METHOD FOR THE MICRODETERMINATION OF ETHANOL [J].
BONNICHSEN, RK ;
THEORELL, H .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1951, 3 (01) :58-62
[3]   EINE SPEZIFISCHE PHOTOMETRISCHE BESTIMMUNG VON ATHYLALKOHOL AUF FERMENTATIVEM WEGE [J].
BUCHER, T ;
REDETZKI, H .
KLINISCHE WOCHENSCHRIFT, 1951, 29 (35-3) :615-616
[4]   VOLTAMMETRIC-ENZYMATIC DETERMINATION OF ETHANOL IN WHOLE-BLOOD BY FLOW-INJECTION ANALYSIS [J].
FERNANDEZ, A ;
DECASTRO, MDL ;
VALCARCEL, M .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 327 (5-6) :552-554
[5]   FLOW-INJECTION ANALYSIS FOR GLUCOSE AND UREA WITH ENZYME REACTORS AND ONLINE DIALYSIS [J].
GORTON, L ;
OGREN, L .
ANALYTICA CHIMICA ACTA, 1981, 130 (01) :45-53
[6]   ANALYSIS OF ALCOHOL .2. REVIEW OF GAS-CHROMATOGRAPHIC METHODS [J].
JAIN, NC ;
CRAVEY, RH .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1972, 10 (05) :263-&
[7]  
JONES D, 1970, CLIN CHEM, V16, P402
[8]  
PELLETIER M, 1981, TRAV CHIM ALIMENT HY, V72, P194
[9]   FLOW-INJECTION ANALYSIS - USE OF IMMOBILIZED ENZYMES FOR THE DETERMINATION OF ETHANOL IN SERUM [J].
RUZ, J ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYST, 1987, 112 (03) :259-261
[10]   FLOW-INJECTION DETERMINATION OF ETHANOL IN WHOLE-BLOOD USING IMMOBILIZED ENZYMES [J].
RUZ, J ;
DECASTRO, MDL ;
VALCARCEL, M .
MICROCHEMICAL JOURNAL, 1987, 36 (03) :316-322