THE RETROGRADE MEDULLARY SUPERIOR PUBIC RAMUS SCREW FOR THE TREATMENT OF ANTERIOR PELVIC RING DISRUPTIONS - A NEW TECHNIQUE

被引:174
作者
ROUTT, MLC
SIMONIAN, PT
GRUJIC, L
机构
[1] Department of Orthopaedics, Harborview Medical Center, Seattle, WA
关键词
RETROGRADE MEDULLARY SUPERIOR PUBIC RAMUS SCREW; ANTERIOR PELVIC RING DISRUPTIONS;
D O I
10.1097/00005131-199502000-00006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Retrograde medullary screws were used in 26 patients with unstable pelvic ring injuries to stabilize the superior pubic ramus fractures. The posterior pelvic ring fractures and dislocations were fixed with iliosacral screws. The retrograde screws were inserted after closed manipulative reductions of the superior pubic ramus fractures in 15 patients and after open reduction in nine patients. We were unable to insert the screw in two patients due to anatomical variations. One screw was misplaced superior to the pubic ramus and noted only on the postoperative computed tomography scan. Another patient experienced symptomatic screw disengagement that required reoperation. All fractures healed and no infections developed. Blood loss was minimal for the percutaneous procedures. The technique provides stability to the anterior pelvic ring without the need for extensile surgical exposures. The complications of both anterior pelvic external fixation and plating are avoided, yet this technique has its own potential problems. The procedure is described in detail, and the early results and complications are documented in our first 26 patients.
引用
收藏
页码:35 / 44
页数:10
相关论文
共 59 条
[1]
Alho A., Horn A., External fixation of pelvic fractures ex vivo, Ann Ghir Gynaecol, 72, pp. 308-311, (1983)
[2]
Brown T., Stone J., Schuster J., Mears D., External fixation of unstable pelvic ring fractures: Comparative rigidity of some current frame configurations, Med Biol Eng Comput, 20, pp. 727-733, (1982)
[3]
Browner B., Cole J., Graham J., Delayed posterior internal fixation of unstable pelvic fractures, J Trauma, 27, pp. 998-1006, (1987)
[4]
Burgess A., Eastridge B., Young J., Pelvic ring disruptions: Effective classification system and treatment protocols, J Trauma, 30, pp. 848-856, (1990)
[5]
Colapinto V., Trauma to the pelvis: Urethral injury, Clin Or-Thop, 151, pp. 46-55, (1980)
[6]
Advanced Trauma Life Support Manual, (1981)
[7]
Dahners L., Jacobs R., Jayaraman G., Cepulo A., A study of external skeletal fixation systems for unstable pelvic fractures, J Trauma, 24, pp. 876-881, (1984)
[8]
Dahners L., Jacobs R., McKenzie E., Gilbert J., Biomechanical studies of an anterior pelvic external fixation frame intended for control of vertical shear fractures, South Med J, 79, pp. 815-817, (1986)
[9]
Ebraheim N., Rusin J., Coombs R., Percutaneous computer tomography-stabilization of pelvic fracture: Preliminary report, J Orthop Trauma, 1, pp. 197-204, (1987)
[10]
Failinger M., McGanity P., Current concepts review. Unstable fractures of the pelvic ring, J Bone Joint Surg [Am], 74, pp. 781-791, (1992)