Use of the Ar-2(+) signal as a diagnostic tool in solid sampling electrothermal vaporization inductively coupled plasma mass spectrometry

被引:50
作者
Vanhaecke, F
Galbacs, G
Boonen, S
Moens, L
Dams, R
机构
关键词
argon dimer (Ar-2(+)); solid sampling electrothermal vaporization; inductively coupled plasma mass spectrometry; matrix effects;
D O I
10.1039/ja9951001047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The utility of the Ar-2(+) signal (at mass-to-charge ratio m/z=80) as a diagnostic tool in solid sampling electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) is reported, Simultaneous monitoring of the argon dimer signal with the signal(s) of the analyte element(s) indicated that non-spectral interferences, caused by matrix components co-volatilizing with the analyte element(s), can strongly affect the analyte signal profiles in solid sampling ETV-ICP-MS of samples of biological or environmental origin, This observation led to a more profound understanding of why, for a given matrix, the signal profiles strongly differ from one element to another, and why, for a given element, the signal profile is seen to be strongly dependent on the matrix, These matrix effects were also observed to cause a curvature in the sample mass response curves (analyte signal intensity as a function of sample mass), It is shown that, at least in some instances, the use of the Ar-2(+) signal as an internal standard allows (i) this non-linearity to be corrected for and (ii) accurate analysis results to be obtained, Finally, it is demonstrated that simultaneous registration of the argon dimer and the analyte signal(s) is useful during optimization of ashing and vaporization temperatures.
引用
收藏
页码:1047 / 1052
页数:6
相关论文
共 19 条
[1]   ELECTROTHERMAL VAPORIZATION INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY FOR THE ANALYSIS OF SEMICONDUCTOR-GRADE ORGANOMETALLIC MATERIALS AND PROCESS CHEMICALS [J].
ARGENTINE, MD ;
BARNES, RM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (12) :1371-1378
[2]   LASER ABLATION OF SOLIDS FOR ELEMENTAL ANALYSIS BY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
ARROWSMITH, P .
ANALYTICAL CHEMISTRY, 1987, 59 (10) :1437-1444
[3]   STUDY OF THE EFFECTS OF CONCOMITANT ELEMENTS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
BEAUCHEMIN, D ;
MCLAREN, JW ;
BERMAN, SS .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (03) :467-490
[4]  
BOONEN S, 1995, IN PRESS SPECTROCH B
[5]  
CHEN X, 1995, IN PRESS J ANAL AT S, V10
[6]  
DENOYER ER, 1994, ATOM SPECTROSC, V15, P7
[7]  
DENOYER ER, 1991, ANAL CHEM, V63, P445
[9]  
GALBACS G, UNPUB