THE TREATMENT OF OSTEOPOROTIC POSTTRAUMATIC VERTEBRAL COLLAPSE USING THE KANEDA DEVICE AND A BIOACTIVE CERAMIC VERTEBRAL PROSTHESIS

被引:109
作者
KANEDA, K
ASANO, S
HASHIMOTO, T
SATOH, S
FUJIYA, M
机构
[1] Department of Orthopaedic Surgery, Hokkaido University School of Medicine, Sapporo
关键词
DELAYED POSTTRAUMATIC VERTEBRAL COLLAPSE; OSTEOPOROTIC VERTEBRAL FRACTURES; ANTERIOR DECOMPRESSION; CERAMIC VERTEBRAL PROSTHESIS; KANEDA DEVICE;
D O I
10.1097/00007632-199208001-00015
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Twenty-two patients with neurologic deficit due to delayed posttraumatic vertebral collapse after osteoporotic compression fractures of the thoracolumbar spine underwent anterior decompression and reconstruction with bioactive Apatite-Wollastonite containing glass ceramic vertebral prosthesis and Kaneda instrumentation. Eighteen patients previously had minor trauma that resulted in a mild vertebral compression fracture without any neurologic involvement and were either conservatively treated or not treated at all. Four had no history of back injury. The preoperative neurologic status was incomplete paralysis in all patients. The average age at surgery was 66 (53-79) years. The average follow-up was 34 (20-58) months after surgery. All patients had returned to their daily living with neurologic recovery and stable spine. This type of anterior procedure is effective in the osteoporotic patients and there was a very low incidence of instrumentation failure and very low morbidity.
引用
收藏
页码:S295 / S303
页数:9
相关论文
共 21 条
[1]  
Adams P.H., Osteoporosis. Clin Rheum Dis, 7, pp. 557-593, (1981)
[2]  
Arciero R.A., Leung K., Pierce J.H., Spontaneous unstable burst fracture of the thoracolumbar spine in osteoporosis: A report of two cases, Spine, 14, pp. 114-117, (1989)
[3]  
Avioli L.V., Osteoporosis, 1, pp. 329-330, (1977)
[4]  
Brower A.C., Downey E.F., : Disease: Report of a case with serial radiographs, Radiology, 141, pp. 363-364, (1981)
[5]  
Denis F., The three column spine and its significance in the classification of the acute thoracolumbar spinal injuries, Spine, 8, pp. 817-832, (1983)
[6]  
Gurr K.R., McAfee P.C., Shih C.M., Biomechanical analysis of anterior and posterior instrumentation system after corpectomy: A calf spine model, J Bone Joint Surg, 70A, pp. 1182-1192, (1988)
[7]  
Hammerberg K.W., Dewald R.L., Senile burst fracture: A complication of osteoporosis, Orthop Trans, 13, (1989)
[8]  
Hermann G., Goldblatt J., Desnick R.J., Kummell disease: Delayed collapse of the traumatised spine in a patient with Gaucher Type 1 disease, Br J Radiol, 57, pp. 833-835, (1984)
[9]  
Kaneda K., Anterior Approach and Kaneda Instrumentation for Lesions of the Thoracic and Lumbar Spine, pp. 959-990, (1991)
[10]  
Kaplan P.A., Orton D.F., Asleson R.J., Osteoporosis with vertebral Compression fractures retropulsed fragments, and neurologic compromise, Radiology, 165, pp. 533-535, (1987)