EFFECT OF INTERFERENCE ON THE PERFORMANCE OF GLUCOSE ENZYME ELECTRODES USING NAFION(R) COATINGS

被引:51
作者
VAIDYA, R [1 ]
ATANASOV, P [1 ]
WILKINS, E [1 ]
机构
[1] UNIV NEW MEXICO, DEPT CHEM & NUCL ENGN, ALBUQUERQUE, NM 87131 USA
基金
美国国家科学基金会;
关键词
ENZYME ELECTRODE; GLUCOSE; NAFION(R); INTERFERENCE;
D O I
10.1016/1350-4533(94)00006-U
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The negatively charged perfluorinated ionomer Nafion(R) was used as a coating on hydrogen peroxide detecting platinum electrode as well as on a polycarbonate diffusion membrane in the construction of a glucose amperometric enzyme electrode. The current response of these electrodes to hydrogen peroxide, ascorbic acid, acetaminophen, uric acid and glucose was studied and the coating procedure was optimized. It was confirmed that the Nafion(R) coating prevents interference by anionic substances such as ascorbic acid and uric acid, and decreases acetaminophen interference. In this regard it was shown that coating the glucose diffusion membrane (polycarbonate) was more effective than coating the platinum wire itself; because of the prevention of the homogeneous redox reaction of the interference species with hydrogen peroxide, as well as the additional diffusional resistance to the glucose flux. The glucose levels in serum samples were estimated and the stability of the enzyme electrodes during continuous operation in serum was studied An enzyme electrode with constant sensitivity of ca. 1 mu A/mM and a linear range of up to 15 mM, unaffected by contact with serum, is reported.
引用
收藏
页码:416 / 424
页数:9
相关论文
共 36 条
[1]  
ABEL P, 1984, BIOMED BIOCHIM ACTA, V43, P577
[2]   AMPEROMETRIC ENZYME ELECTRODES .2. CONDUCTING SALTS AS ELECTRODE MATERIALS FOR THE OXIDATION OF GLUCOSE-OXIDASE [J].
ALBERY, WJ ;
BARTLETT, PN ;
CRASTON, DH .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 194 (02) :223-235
[3]   APPLICATION OF CHRONIC INTRAVASCULAR BLOOD-GLUCOSE SENSOR IN DOGS [J].
ARMOUR, JC ;
LUCISANO, JY ;
MCKEAN, BD ;
GOUGH, DA .
DIABETES, 1990, 39 (12) :1519-1526
[4]   AN AMPEROMETRIC ENZYME ELECTRODE FOR MONITORING BRAIN GLUCOSE IN THE FREELY MOVING RAT [J].
BOUTELLE, MG ;
STANFORD, C ;
FILLENZ, M ;
ALBERY, WJ ;
BARTLETT, PN .
NEUROSCIENCE LETTERS, 1986, 72 (03) :283-288
[5]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[6]   BIOCATALYTIC OXIDATION OF GLUCOSE ON THE CONDUCTIVE CHARGE-TRANSFER COMPLEXES [J].
CENAS, NK ;
KULYS, JJ .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1981, 8 (01) :103-113
[7]   AMPEROMETRIC NEEDLE-TYPE GLUCOSE SENSOR BASED ON A MODIFIED PLATINUM-ELECTRODE WITH DIMINISHED RESPONSE TO INTERFERING MATERIALS [J].
CHEN, CY ;
GOTOH, M ;
MAKINO, H ;
SU, YC ;
TAMIYA, E ;
KARUBE, I .
ANALYTICA CHIMICA ACTA, 1992, 265 (01) :5-14
[8]   SUBCUTANEOUS IMPLANTATION OF A FERROCENE-MEDIATED GLUCOSE SENSOR IN PIGS [J].
CLAREMONT, DJ ;
SAMBROOK, IE ;
PENTON, C ;
PICKUP, JC .
DIABETOLOGIA, 1986, 29 (11) :817-821
[9]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[10]   IMPLANTED ELECTROENZYMATIC GLUCOSE SENSORS [J].
CLARK, LC ;
DUGGAN, CA .
DIABETES CARE, 1982, 5 (03) :174-180