FUEL EQUIVALENCE RATIO IMAGING FOR METHANE JETS

被引:20
作者
NI, TQ [1 ]
MELTON, LA [1 ]
机构
[1] UNIV TEXAS,DEPT CHEM,RICHARDSON,TX 75083
关键词
FLUORESCENCE; INSTRUMENTATION; IMAGING; ANALYTICAL METHODS; TIME-RESOLVED SPECTROSCOPY;
D O I
10.1366/0003702934066910
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A 2-D fuel/oxygen equivalence ratio imaging system has been developed. The technique exploits the efficient quenching of the fluorescence of organic molecules by molecular oxygen in order to determine the fuel and oxygen partial pressures simultaneously. Following pulsed planar laser excitation of fluoranthene-a specially selected fluorescent dopant-two images of the fluorescence were recorded, with the second image being delayed by several nanoseconds. Use of a rapid lifetime determination algorithm yielded first a fluorescence lifetime image, and subsequently, with the assumption of Stern-Volmer quenching, an intensity image corrected for quenching. Images of the air pressure, fuel pressure, and the equivalence ratio were obtained. The technique, which uses dual gated intensifiers coupled to a sensitive CCD camera, requires only two integrated fluorescence intensities to calculate the fluorescence lifetime accurately. In the current work, images of the turbulence-induced mixing of a methane jet into quiescent air are displayed. Images can also be obtained in flames, but the analysis of the data is uncertain because the fluorescence lifetime of fluoranthene is temperature dependent.
引用
收藏
页码:773 / 781
页数:9
相关论文
共 14 条
[1]   AN ERROR ANALYSIS OF THE RAPID LIFETIME DETERMINATION METHOD FOR THE EVALUATION OF SINGLE EXPONENTIAL DECAYS [J].
BALLEW, RM ;
DEMAS, JN .
ANALYTICAL CHEMISTRY, 1989, 61 (01) :30-33
[2]   OBSERVATION OF DUAL FLUORESCENCE FOR FLUORANTHENE IN THE VAPOR-PHASE [J].
BARK, KM ;
FORCE, RK .
JOURNAL OF PHYSICAL CHEMISTRY, 1989, 93 (24) :7985-7988
[3]   OPERATION OF A 1P28 PHOTOMULTIPLIER WITH SUBNANOSECOND RESPONSE-TIME [J].
BECK, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1976, 47 (05) :537-541
[4]  
BERLMAN IB, 1971, HDB FLUORESCENCE ARO
[5]   FLUORESCENCE LIFETIME REFERENCE STANDARDS FOR RANGE 0.189 TO 115 NANOSECONDS [J].
CHEN, RF .
ANALYTICAL BIOCHEMISTRY, 1974, 57 (02) :593-604
[6]   TWO-DIMENSIONAL IMAGING OF OH LASER-INDUCED FLUORESCENCE IN A FLAME [J].
DYER, MJ ;
CROSLEY, DR .
OPTICS LETTERS, 1982, 7 (08) :382-384
[7]   PLANAR LASER-FLUORESCENCE IMAGING OF COMBUSTION GASES [J].
HANSON, RK ;
SEITZMAN, JM ;
PAUL, PH .
APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1990, 50 (06) :441-454
[8]   DETERMINATION OF POLYNUCLEAR AROMATIC-HYDROCARBONS IN VAPOR-PHASES BY LASER-INDUCED MOLECULAR FLUORESCENCE [J].
JANDRIS, LJ ;
FORCE, RK .
ANALYTICA CHIMICA ACTA, 1983, 151 (01) :19-27
[9]  
JANDRIS LJ, 1984, APPL SPECTROSC, V39, P266
[10]  
MELTON LA, UNPUB