INTRASUBJECT RELIABILITY OF SPINAL RANGE OF MOTION AND VELOCITY DETERMINED BY VIDEO MOTION ANALYSIS

被引:19
作者
ROBINSON, ME
OCONNOR, PD
SHIRLEY, FR
MACMILLAN, M
机构
[1] UNIV FLORIDA, CTR MUSCULOSKELETAL RES, DEPT CLIN & HLTH PSYCHOL, GAINESVILLE, FL 32610 USA
[2] UNIV FLORIDA, DEPT ORTHOPAED, GAINESVILLE, FL 32610 USA
[3] SHANDS TEACHING HOSP & CLIN INC, SPINAL TREATMENT & REHABIL PROGRAM, GAINESVILLE, FL 32610 USA
来源
PHYSICAL THERAPY | 1993年 / 73卷 / 09期
关键词
BACKACHE; MOVEMENT SCIENCE; SPINE; TESTS AND MEASUREMENTS; RANGE OF MOTION;
D O I
10.1093/ptj/73.9.626
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background and Purpose. The purpose of this study was to investigate the repeatability of spinal range of motion (ROM) and movement velocity measurements of patients with chronic low back pain, using a two-dimensional motion analysis system. This apparatus uses reflective markers placed on anatomical landmarks and video digitization to derive ROM measurements from three segments of the spine and associated velocities through the respective ROMs. Subjects. Forty-two patients with chronic LBP underwent ROM and movement velocity testing. Methods. Each subject was tested twice without removal of the markers to minimize error contribution from differences in marker placement. Results. Results indicated that both the ROM measures and the velocity measures were highly repeatable intra-class correlations for the ROM measures ranged from .77 to .96. Velocity measures were also reliable, with intraclass correlation coefficients ranging from .75 to .97 Conclusion and Discussion. Overall, the results seem to indicate that the video motion analysis system used in this system yields repeatable ROM and velocity measures on a clinical population. In practice, however, the measures may reflect greater errors due to the need of examiners to relocate markers at different testing sessions. These system also offer distinct advantages over other means of obtaining ROM and velocity measures. The results of this study indicate that these measures may be obtained without undue concern for measurement artifact due to the instrumentation reliability.
引用
收藏
页码:626 / 631
页数:6
相关论文
共 22 条
[1]  
ANDERSON J A D, 1975, Rheumatology and Rehabilitation, V14, P173, DOI 10.1093/rheumatology/14.3.173
[2]   RELIABILITY OF THE ATTRACTION METHOD FOR MEASURING LUMBAR SPINE BACKWARD BENDING [J].
BEATTIE, P ;
ROTHSTEIN, JM ;
LAMB, RL .
PHYSICAL THERAPY, 1987, 67 (03) :364-369
[3]   PHYSICAL MEASUREMENTS AS RISK INDICATORS FOR LOW-BACK TROUBLE OVER A ONE-YEAR PERIOD [J].
BIERINGSORENSEN, F .
SPINE, 1984, 9 (02) :106-119
[4]   RELIABILITY OF CLINICAL MEASUREMENTS OF FORWARD BENDING USING THE MODIFIED FINGERTIP-TO-FLOOR METHOD [J].
GAUVIN, MG ;
RIDDLE, DL ;
ROTHSTEIN, JM .
PHYSICAL THERAPY, 1990, 70 (07) :443-447
[5]   NORMATIVE DATABASE FOR TRUNK RANGE OF MOTION, STRENGTH, VELOCITY, AND ENDURANCE WITH THE ISOSTATION B-200 LUMBAR DYNAMOMETER [J].
GOMEZ, T ;
BEACH, G ;
COOKE, C ;
HRUDEY, W ;
GOYERT, P .
SPINE, 1991, 16 (01) :15-21
[6]  
GRACOVETSKY S, 1988, 5TH P BIENN C HUM LO, P68
[7]   REPEATABILITY OF KINEMATIC, KINETIC, AND ELECTROMYOGRAPHIC DATA IN NORMAL ADULT GAIT [J].
KADABA, MP ;
RAMAKRISHNAN, HK ;
WOOTTEN, ME ;
GAINEY, J ;
GORTON, G ;
COCHRAN, GVB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (06) :849-860
[8]  
Loebl W Y, 1967, Ann Phys Med, V9, P103
[9]  
LOESER JD, 1990, MANAGEMENT PAIN
[10]   MEASUREMENT OF BACK MOVEMENT [J].
MACRAE, IF ;
WRIGHT, V .
ANNALS OF THE RHEUMATIC DISEASES, 1969, 28 (06) :584-&