DYNAMIC-RANGE REQUIREMENTS IN DIGITAL MAMMOGRAPHY

被引:41
作者
MAIDMENT, ADA
FAHRIG, R
YAFFE, MJ
机构
[1] UNIV TORONTO,DEPT MED BIOPHYS,TORONTO M4N 3M5,ON,CANADA
[2] UNIV TORONTO,DEPT RADIOL,TORONTO M4N 3M5,ON,CANADA
[3] SUNNYBROOK HLTH SCI CTR,DIV RES,TORONTO M4N 3M5,ON,CANADA
关键词
DIGITAL MAMMOGRAPHY; DYNAMIC RANGE; DOSE; SIGNAL-TO-NOISE RATIO; DETECTOR DESIGN;
D O I
10.1118/1.596949
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The dynamic range and the number of gray levels, GAMMA(s), required for digital mammography has been evaluated using an energy transport model. The effects of molybdenum (Mo) and tungsten (W) target spectra and the energy-dependent attenuation by elemental filters, breast tissue, and a phosphor screen were included in the model. For detectors with ideal optical coupling and no inherent detector noise, 3 100 gray levels are discernable (requiring 12 bits per pixel), assuming a 40 kVp, W target spectrum (1.0 mm Al filtration), a mean glandular dose to a 5 cm thick breast of 0.6 mGy, and an ideal observer with a 5 mm diam viewing aperture. The effects of inherent detector noise and realistic coupling efficiencies on GAMMA(s), were also examined. For the 40 kVp, W spectrum, a detector with total coupling efficiency of 16 electrons (e-) per x-ray interaction and a dynamic range of 3000 (maximum carrier signal of 1.93 X 105 e- /pixel and inherent detector noise of 64 e- pixel) would decrease the number of gray levels that could be resolved by only 2% compared to a detector with ideal coupling and no inherent noise. A detector with a total coupling efficiency of 2.0 electrons per x-ray interaction and a dynamic range of 240 (maximum carrier signal 2.41 X 10(4) e-/pixel and inherent detector noise of 100;; e-/pixel) would reduce the number of gray levels by 26% for the 40 kVp spectrum. On the basis of dynamic range, W spectra are preferable for digital mammography, since Mo spectra yielding the same signal-to-noise ratio require a detector with dynamic range twice as large, and with a 30% greater saturation signal. When no scatter rejection method is used, scattered radiation over a 254 cm 2 imaging field reduces the number of discernable gray levels by 23% for a 5 cm thick breast and 34% for an 8 cm thick breast.
引用
收藏
页码:1621 / 1633
页数:13
相关论文
共 46 条
[1]   INTENSITY OF SCATTERED RADIATION IN MAMMOGRAPHY [J].
BARNES, GT ;
BREZOVICH, IA .
RADIOLOGY, 1978, 126 (01) :243-247
[2]   RADIOGRAPHIC MOTTLE AND PATIENT EXPOSURE IN MAMMOGRAPHY [J].
BARNES, GT ;
CHAKRABORTY, DP .
RADIOLOGY, 1982, 145 (03) :815-821
[3]  
BIRCH R, 1979, CATALOGUE SPECTRAL D, P134
[4]  
Bunch P. C., 1986, Proceedings of the SPIE - The International Society for Optical Engineering, V626, P64, DOI 10.1117/12.975378
[5]  
CARLSSON GA, 1989, ULIRADR059 U LINK RE
[6]  
Chang Hyun, 1988, MONTE CARLO SIMULATI, P156
[7]   CALCULATION OF DOSE AND CONTRAST FOR 2 MAMMOGRAPHIC GRIDS [J].
DANCE, DR ;
PERSLIDEN, J ;
CARLSSON, GA .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (01) :235-248
[8]   THE COMPUTATION OF SCATTER IN MAMMOGRAPHY BY MONTE-CARLO METHODS [J].
DANCE, DR ;
DAY, GJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (03) :237-247
[9]  
DANCE DR, 1981, P PATIENT EXPOSURE R, P227
[10]  
DERENIAK EL, 1984, OPTICAL RAD DETECTOR, pCH9