A COMPARISON OF HEMOLYTIC AND SONOCHEMICAL ACTIVITY OF ULTRASONIC CAVITATION IN A ROTATING TUBE

被引:21
作者
MILLER, DL
THOMAS, RM
机构
[1] Biology and Chemistry Department, Battelle Pacific Northwest Laboratories, Richland, WA 99352
关键词
BIOLOGICAL EFFECTS; CELL LYSIS; HYDROGEN PEROXIDE; FREE RADICALS; DOSIMETRY; MECHANISMS;
D O I
10.1016/0301-5629(93)90021-F
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Biological effects of in vitro ultrasonic exposure may result from mechanical and from sonochemical mechanisms related to ultrasonic cavitation. Mechanical cell lysis by 1.61 MHz ultrasonic cavitation was assessed in a rotating tube exposure system by hemolysis measurements. Free radical generation was assessed by the terephthalic acid dosimeter, calibrated by gamma-ray dosage. Sonochemical production was assessed by measuring residual hydrogen peroxide using the sensitive isoluminol method. Exposure conditions were similar for all tests, except longer durations were needed for the free radical and hydrogen peroxide tests. The sonochemical mechanisms were relatively more important for increasing intensity, and increasing temperature. Increasing rotation speed or bubbling with argon before exposure enhanced all cavitation activity. Stopping the rotation reduced all cavitation activity. Burst-mode ultrasound (10.5 mus bursts, 1:1 or 1:3 duty cycle) reduced cavitation activity, but gave relatively greater sonochemical activity under some conditions. These results indicate that the mechanical and sonochemical mechanisms can be separately favored to some extent by varying exposure conditions. The observed trends should be helpful for selecting exposure conditions favorable for studying bioeffects of the sonochemical mechanism.
引用
收藏
页码:83 / 90
页数:8
相关论文
共 13 条
[1]   PULSED ENHANCEMENT OF ACOUSTIC CAVITATION - A POSTULATED MODEL [J].
CIARAVINO, V ;
FLYNN, HG ;
MILLER, MW .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1981, 7 (02) :159-166
[2]   PHYSICAL AND CHEMICAL ASPECTS OF ULTRASONIC DISRUPTION OF CELLS [J].
CLARKE, PR ;
HILL, CR .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1970, 47 (02) :649-&
[3]   CAVITATIONAL BIO-EFFECTS AT 1.5 MHZ [J].
GRAHAM, E ;
HEDGES, M ;
LEEMAN, S ;
VAUGHAN, P .
ULTRASONICS, 1980, 18 (05) :224-228
[4]   EFFECT OF FREE-RADICALS INDUCED BY ULTRASONIC CAVITATION ON CELL KILLING [J].
KONDO, T ;
KANO, E .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1988, 54 (03) :475-486
[5]   A CAVITATION AND FREE-RADICAL DOSIMETER FOR ULTRASOUND [J].
MCLEAN, JR ;
MORTIMER, AJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1988, 14 (01) :59-64
[6]   BUBBLE CYCLING AS THE EXPLANATION OF THE PROMOTION OF ULTRASONIC CAVITATION IN A ROTATING TUBE EXPOSURE SYSTEM [J].
MILLER, DL ;
WILLIAMS, AR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (07) :641-648
[7]   SINGLE-STRAND BREAKS IN CHO CELL-DNA INDUCED BY ULTRASONIC CAVITATION INVITRO [J].
MILLER, DL ;
THOMAS, RM ;
FRAZIER, ME .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (04) :401-406
[8]   ULTRASONIC CAVITATION INDIRECTLY INDUCES SINGLE-STRAND BREAKS IN DNA OF VIABLE CELLS-INVITRO BY THE ACTION OF RESIDUAL HYDROGEN-PEROXIDE [J].
MILLER, DL ;
THOMAS, RM ;
FRAZIER, ME .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (07) :729-735
[10]   THE EXPOSURE VESSEL AS A FACTOR IN ULTRASONICALLY-INDUCED MAMMALIAN-CELL LYSIS .1. A COMPARISON OF TUBE AND CHAMBER SYSTEMS [J].
SACKS, PG ;
MILLER, MW ;
CHURCH, CC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1982, 8 (03) :289-298