PROBABILISTIC ANALYSIS OF LIMITING CONDITIONS FOR OPERATION ACTION REQUIREMENTS INCLUDING RISK OF SHUTDOWN

被引:1
作者
MANKAMO, T [1 ]
KIM, IS [1 ]
SAMANTA, PK [1 ]
机构
[1] BROOKHAVEN NATL LAB,DEPT ADV TECHNOL,UPTON,NY 11973
关键词
D O I
10.13182/NT95-A35178
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
When the systems needed to shut down a nuclear power plant are inoperable or degraded, the risk of shutting down the plant may be comparable to, or even higher than, that of continuing power operation with the equipment inoperable but giving priority to repairs. This concern arises because the plant may have insufficient capability for removing decay heat during the shutdown. However in many cases, plant technical specifications require immediate shutdown of the plant. Risk-based analyses for various alternatives of operational policy available in such situations are examined. These analyses can be used to define the risk-effective requirements for those standby safety systems.
引用
收藏
页码:250 / 265
页数:16
相关论文
共 13 条
[1]  
ANDRE GR, 1993, TR101894 EL POW RES
[2]  
DROUIN MT, 1989, NUREGCR4550 US NUC 1, V6
[3]   RISK ANALYSIS OF SURVEILLANCE REQUIREMENTS INCLUDING THEIR ADVERSE-EFFECTS [J].
KIM, IS ;
MARTORELL, SA ;
VESELY, WE ;
SAMANTA, PK .
RELIABILITY ENGINEERING & SYSTEM SAFETY, 1994, 45 (03) :225-234
[4]  
KIM IS, 1994, BNL L1692 TECHN REP
[6]  
MANKAMO T, 1989, 1989 PROB SAF ASS IN, P1131
[7]  
MANKAMO T, 1992, TECDOC IAEAJ4CS5392
[8]  
MANKAMO T, 1993, NUREGCR5995 US NUCL
[9]  
MANKAMO T, 1994, BNL L2289 TECHN REP
[10]  
SAMANTA PK, 1994, NUREGCR6141 US NUCL