NON-PASSIVE CHLORIDE DISTRIBUTION IN MAMMALIAN HEART-MUSCLE - MICROELECTRODE MEASUREMENT OF THE INTRACELLULAR CHLORIDE ACTIVITY

被引:116
作者
VAUGHANJONES, RD
机构
来源
JOURNAL OF PHYSIOLOGY-LONDON | 1979年 / 295卷 / OCT期
关键词
D O I
10.1113/jphysiol.1979.sp012956
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
1. Liquid ion‐exchanger Cl‐ ‐sensitive micro‐electrodes were used to make continuous measurements of the intracellular Cl activity, aCli, of quiscent sheep cardiac Purkinje fibres in vitro. 2. aCli was higher than that expected from a passive distribution, (which would have been about 5 mM). It was 3‐‐4 times hiable; EC1 was about 35 mV positive to Em. It was over twice as high in the nominal absence of bicarbonate/CO2 (when the buffer‐system was HEPES/O2) but was not always so stable, and ECl was about 20 mV positive to Em. 3. Experiments designed to assess the maximum possible error likely to occur in the measurement of aCli showed that this could not be large and that the estimates of ECl were accurate to within 8 mV. 4. The ability of Cl to move down both concentration and potential gradients was established by demonstrating a loss of aCli in Cl‐free solutions and a gain when Em was depolarized positive to ECl in high‐K solutions. In both cases, the changes were complete within about 100‐‐160 min. 5. The decline of aCli in Cl‐free solutions (glucuronate‐substituted) was not significantly affected by changes of [Ca]o from 0 to 12 mM or by the depolarizations of Em of up to 60 mV that sometimes occurred in low or zero [Ca]o. 6. Only 2‐‐3 mM‐aClo was sufficient to impede substantially the ready loss of aCli in HEPES‐buffered solutions. 7. In high‐K solutions (45 mM), Cl appeared to be passively distributed since, at equilibrium, Em and ECl differed by less than 2 mV. 8. In HEPES‐buffered Tyrode, ECl of quiescent papillary muscle of the guinea‐pig was, on average, 39 mV positive to Em. 9. It is concluded that liquid ion‐exchanger Cl‐ ‐sensitive micro‐electrodes are suitable for studying the Cl regulation of sheep Prukinje fibres, and probably of other cardiac tissues. The measurements of resting aCli are quite accurate when using either HEPES or bicarbonate‐buffered Tyrode. The results are discussed in relation to estimates of the apparent membrane Cl permeability under various conditions and the possible existence of an inwardly directed ‘Cl pump'. © 1979 The Physiological Society
引用
收藏
页码:83 / 109
页数:27
相关论文
共 45 条
[1]  
[Anonymous], 1966, NERVE MUSCLE SYNAPSE
[2]   CHLORIDE DISTRIBUTION IN APLYSIA NEURONS [J].
ASCHER, P ;
KUNZE, D ;
NEILD, TO .
JOURNAL OF PHYSIOLOGY-LONDON, 1976, 256 (02) :441-464
[3]  
BARKER J L, 1975, Journal of Membrane Biology, V25, P361, DOI 10.1007/BF01868584
[4]  
BOLTON TB, 1976, J PHYSIOL-LONDON, V260, pP6
[5]   CONTINUOUS DIRECT MEASUREMENT OF INTRACELLULAR CHLORIDE AND PH IN FROG SKELETAL-MUSCLE [J].
BOLTON, TB ;
VAUGHANJONES, RD .
JOURNAL OF PHYSIOLOGY-LONDON, 1977, 270 (03) :801-833
[6]   ANALYSIS OF EFFLUXES OF SODIUM, POTASSIUM AND CHLORIDE IONS FROM SMOOTH MUSCLE IN NORMAL AND HYPERTONIC SOLUTIONS [J].
BRADING, AF .
JOURNAL OF PHYSIOLOGY-LONDON, 1971, 214 (03) :393-&
[7]  
CARMELIE.EE, 1965, ARCH INT PHYS BIOCH, V73, P174
[8]   REDUCTION OF POTASSIUM PERMEABILITY BY CHLORIDE SUBSTITUTION IN CARDIAC CELLS [J].
CARMELIET, E ;
VERDONCK, F .
JOURNAL OF PHYSIOLOGY-LONDON, 1977, 265 (01) :193-206
[9]   COUPLING BETWEEN C1-FLUX AND NA-OR-K-FLUX IN CARDIAC PURKYNE FIBERS INFLUENCE OF PH [J].
CARMELIET, E ;
BOSTEELS, S .
ARCHIVES INTERNATIONALES DE PHYSIOLOGIE ET DE BIOCHIMIE, 1969, 77 (01) :57-+
[10]   CHLORIDE IONS AND MEMBRANE POTENTIAL OF PURKINJE FIBRES [J].
CARMELIET, E .