IMAGE QUALITY OF DIGITAL CHEST RADIOGRAPHY - EVALUATION OF SUBTLE INTERSTITIAL LUNG ABNORMALITIES - (PRELIMINARY-STUDY)

被引:1
作者
IKEZOE, J
KIDO, S
TAKEUCHI, N
KONDOH, H
ARISAWA, J
KOZUKA, T
机构
[1] Department of Radiology, Osaka University Medical School, Suita City, Osaka
关键词
IMAGE QUALITY; DIGITAL RADIOGRAPHY; STORAGE PHOSPHOR RADIOGRAPHY; RECEIVER OPERATING CHARACTERISTIC ANALYSIS;
D O I
10.1016/0169-2607(94)90195-3
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
To evaluate the image quality of storage phosphor radiography (SR) for diagnosing subtle interstitial lung abnormalities, we studied the differences between conventional screen-film radiography (FR) and SR in 38 patients. Nineteen patients had subtle interstitial lung abnormalities and the others had normal chests. Two formats of hard copies were used for SR; a full-size SR (14 x 14 inches, 0.2-mm pixel size) and a minified SR (9 x 9 inches, 0.13-mm pixel size). Readings were carried out by 14 readers (7 chest radiologists and 7 residents). The area under the receiver operating characteristic curve was used to evaluate the results. For the 14 readers no significant differences in observer performance were observed among the three image sets (FR, full-size SR, minified SR), while for the seven chest radiologists significant differences were observed between FR and the two formats of SR. The best perceptual accuracy was obtained with FR as evaluated by the seven chest radiologists. In conclusion, while overall performance with digital and conventional radiographs was almost the same as far as diagnosing subtle interstitial lung abnormalities, significant differences between FR and SR were found by chest radiologists. Critically important information may be lost in commercially available SR.
引用
收藏
页码:107 / 114
页数:8
相关论文
共 15 条
[1]   MAXIMUM-LIKELIHOOD ESTIMATION OF PARAMETERS OF SIGNAL-DETECTION THEORY AND DETERMINATION OF CONFIDENCE INTERVALS - RATING-METHOD DATA [J].
DORFMAN, DD ;
ALF, E .
JOURNAL OF MATHEMATICAL PSYCHOLOGY, 1969, 6 (03) :487-&
[2]   EFFICACY OF DIGITAL RADIOGRAPHY FOR THE DETECTION OF PNEUMOTHORAX - COMPARISON WITH CONVENTIONAL CHEST RADIOGRAPHY [J].
ELAM, EA ;
REHM, K ;
HILLMAN, BJ ;
MALONEY, K ;
FAJARDO, LL ;
MCNEILL, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (03) :509-514
[3]   DETECTION OF PNEUMOTHORAX - COMPARISON OF DIGITAL AND CONVENTIONAL CHEST IMAGING [J].
FAJARDO, LL ;
HILLMAN, BJ ;
POND, GD ;
CARMODY, RF ;
JOHNSON, JE ;
FERRELL, WR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (03) :475-480
[4]   DIGITAL IMAGING OF THE CHEST [J].
FRASER, RG ;
SANDERS, C ;
BARNES, GT ;
MACMAHON, H ;
GIGER, ML ;
DOI, K ;
TEMPLETON, AW ;
COX, GG ;
DWYER, SJ ;
MERRITT, CRB ;
JONES, JP .
RADIOLOGY, 1989, 171 (02) :297-307
[5]   HIGH-RESOLUTION DIGITAL IMAGING WITH STORAGE PHOSPHORS [J].
FUHRMAN, CR ;
GUR, D ;
SCHAETZING, R .
JOURNAL OF THORACIC IMAGING, 1990, 5 (01) :21-30
[6]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[7]   INTERPRETATION OF SUBTLE INTERSTITIAL LUNG ABNORMALITIES - CONVENTIONAL VERSUS STORAGE PHOSPHOR RADIOGRAPHY [J].
KIDO, S ;
IKEZOE, J ;
TAKEUCHI, N ;
KONDOH, H ;
TOMIYAMA, N ;
JOKOH, T ;
KOHNO, N ;
TAKASHIMA, S ;
YAMAGAMI, H ;
NAITO, H ;
ARISAWA, J ;
MORIMOTO, S ;
KOZUKA, T .
RADIOLOGY, 1993, 187 (02) :527-533
[8]   SPATIAL-RESOLUTION REQUIREMENTS FOR DIGITAL CHEST RADIOGRAPHS - AN ROC STUDY OF OBSERVER PERFORMANCE IN SELECTED CASES [J].
LAMS, PM ;
COCKLIN, ML .
RADIOLOGY, 1986, 158 (01) :11-19
[9]   DIGITAL RADIOGRAPHY OF SUBTLE PULMONARY ABNORMALITIES - AN ROC STUDY OF THE EFFECT OF PIXEL SIZE ON OBSERVER PERFORMANCE [J].
MACMAHON, H ;
VYBORNY, CJ ;
METZ, CE ;
DOI, K ;
SABETI, V ;
SOLOMON, SL .
RADIOLOGY, 1986, 158 (01) :21-26
[10]   PRELIMINARY EXPERIENCE WITH PORTABLE DIGITAL IMAGING FOR INTENSIVE-CARE RADIOGRAPHY [J].
MARGLIN, SI ;
ROWBERG, AH ;
GODWIN, JD .
JOURNAL OF THORACIC IMAGING, 1990, 5 (01) :49-54