EFFECTS OF SYSTOLIC AND DIASTOLIC POSITIVE PLEURAL PRESSURE PULSES WITH ALTERED CARDIAC CONTRACTILITY

被引:21
作者
FESSLER, HE
BROWER, RG
WISE, RA
PERMUTT, S
机构
[1] Div. of Pulmonary/Critical Care Med., Johns Hopkins Asthma/Allergy Center, Francis Scott Key Medical Center, Baltimore, MD 21224
关键词
HEART FAILURE; CARDIAC ASSIST; CARDIOPULMONARY INTERACTIONS; VENOUS RETURN; CARDIAC OUTPUT;
D O I
10.1152/jappl.1992.73.2.498
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Positive pleural pressure (Ppl) decreases left ventricular afterload and preload. The resulting change in cardiac output (CO) in response to these altered loading conditions varies with the baseline level of cardiac contractility. In an isolated canine heart-lung preparation, we studied the effects of positive Ppl applied phasically during systole or diastole on CO and on the cardiac function curve (the relationship between CO and left atrial transmural pressure). When baseline cardiac contractility was enhanced by epinephrine infusion, systolic and diastolic positive Ppl decreased CO equally (1,931 +/- 131 to 1,419 +/- 124 and 1,970 +/- 139 to 1,468 +/-139 ml/min, P < 0.01) and decreased the pressure gradient driving venous return. However, neither shifted the position of the cardiac function curve, suggesting that the predominant effect of positive Ppl was decreased preload. When baseline cardiac contractility was depressed by severe respiratory acidosis, diastolic positive Ppl pulses caused no significant change in CO (418 +/- 66 to 386 +/- 52 ml/min), the cardiac function curve, or the pressure gradient for venous return. However, systolic positive Ppl pulses increased CO from 415 +/- 70 to 483 +/- 65 ml/min (P < 0.01) and significantly shifted the cardiac function curve to the left. Thus the effect of Ppl pulsations on CO works through different mechanisms, depending on the state of cardiac contractility.
引用
收藏
页码:498 / 505
页数:8
相关论文
共 28 条
[1]   REFLEX DEPRESSION OF CARDIOVASCULAR FUNCTION DURING LUNG-INFLATION [J].
ASHTON, JH ;
CASSIDY, SS .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 58 (01) :137-145
[2]  
BEYAR R, 1984, T AM SOC ART INT ORG, V30, P103
[3]  
BEYAR R, 1989, CIRC RES, V64, P706
[4]  
BRAUNWALD W, 1957, CIRC RES, V5, P670
[5]   EFFECT OF LUNG-INFLATION ON LUNG BLOOD-VOLUME AND PULMONARY VENOUS FLOW [J].
BROWER, R ;
WISE, RA ;
HASSAPOYANNES, C ;
BROMBERGERBARNEA, B ;
PERMUTT, S .
JOURNAL OF APPLIED PHYSIOLOGY, 1985, 58 (03) :954-963
[6]   EFFECT OF INTRA-THORACIC PRESSURE ON LEFT-VENTRICULAR PERFORMANCE [J].
BUDA, AJ ;
PINSKY, MR ;
INGELS, NB ;
DAUGHTERS, GT ;
STINSON, EB ;
ALDERMAN, EL .
NEW ENGLAND JOURNAL OF MEDICINE, 1979, 301 (09) :453-459
[7]   EFFECT ON PULMONARY VASCULAR RESISTANCE OF INFLATION OF THE RABBIT LUNGS [J].
BURTON, AC ;
PATEL, DJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1958, 12 (02) :239-246
[8]   MECHANISM OF REDUCED LV AFTERLOAD BY SYSTOLIC AND DIASTOLIC POSITIVE PLEURAL PRESSURE [J].
FESSLER, HE ;
BROWER, RG ;
WISE, RA ;
PERMUTT, S .
JOURNAL OF APPLIED PHYSIOLOGY, 1988, 65 (03) :1244-1250
[9]   EFFECTS OF POSITIVE END-EXPIRATORY PRESSURE ON THE GRADIENT FOR VENOUS RETURN [J].
FESSLER, HE ;
BROWER, RG ;
WISE, RA ;
PERMUTT, S .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 143 (01) :19-24
[10]   MECHANISM OF DECREASED RIGHT AND LEFT-VENTRICULAR END-DIASTOLIC VOLUMES DURING CONTINUOUS POSITIVE-PRESSURE VENTILATION IN DOGS [J].
FEWELL, JE ;
ABENDSCHEIN, DR ;
CARLSON, CJ ;
RAPAPORT, E ;
MURRAY, JF .
CIRCULATION RESEARCH, 1980, 47 (03) :467-472