ATRIAL-PACING LEADS - THE CLINICAL CONTRIBUTION OF STEROID ELUTION

被引:18
作者
MOND, HG
HUA, W
WANG, CC
机构
[1] Department of Cardiology, Royal Melbourne Hospital, Melbourne
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1995年 / 18卷 / 09期
关键词
STEROID-ELATING ATRIAL LEADS; ACTIVE FIXATION; PASSIVE FIXATION;
D O I
10.1111/j.1540-8159.1995.tb06981.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Although the original atrial pacing leads were passive fixation and J shaped for right atrial appendage placement, the subsequent development of the active fixation screw-in lead found favor because of a perceived low incidence of lead dislodgment and a wider selection of atrial pacing sites. A bipolar atrial lead study was undertaken to compare the long-term atrial implant data in 225 patients. Study leads comprised one passive fixation, steroid-eluting lead (Medtronic CapSure(R) SP, 119 patients) and three nonsteroid-eluting leads; two active fixation (Medtronic BISPING(R) model 4058, 30 patients; and Telectronics ACCUFIX(R) model 330-801, 44 patients) and one passive fixation (Telectronics ENCOR(R) model 330-854, 22 patients). Bipolar atrial voltage stimulation thresholds and electrograms were measured using the Telectronics META(R) DDDR immediately postimplantation, and at 1-, 3-, 6-, 22-, and 18-month follow-up. There were 135 males and the mean age 68 years. The incidence of lead dislodgment was 4% for active fixation and 2% for passive fixation. All nonsteroid leads showed a typical rise in stimulation thresh old with the highest being the ACCUFIX followed by the BISPING and ENCOR. The steroid-eluting CapSure SP, however, demonstrated a flat response with 98% of leads at 18 months having a value less than or equal to 1.3 volts allowing voltage programming to 2.5 volts (2:1 safety ratio). Telemeted electrograms showed no differences for all leads at all visits. For low voltage atrial pacing with a low incidence of dislodgment and satisfactory atrial sensing, the steroid-eluting passive fixation lead is superior to all nonsteroid-eluting leads.
引用
收藏
页码:1601 / 1608
页数:8
相关论文
共 31 条
  • [1] AONUMA K, 1988, PACE, V11, P510
  • [2] 3-YEAR CLINICAL-EXPERIENCE WITH A NEW ENDOCARDIAL SCREW-IN LEAD WITH INTRODUCTION PROTECTION FOR USE IN THE ATRIUM AND VENTRICLE
    BISPING, HJ
    KREUZER, J
    BIRKENHEIER, H
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1980, 3 (04): : 424 - 435
  • [3] CHURCH T, 1987, PACE, V10, P659
  • [4] TREATMENT OF PATIENTS WITH PRIOR EXIT BLOCK USING A NOVEL STEROID-ELUTING ACTIVE FIXATION LEAD
    CROSSLEY, GH
    REYNOLDS, D
    KAY, GN
    FERGUSON, TB
    LAMAS, G
    MESSENGER, J
    ZMIJEWSKI, M
    BRINKER, JA
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11): : 2042 - 2046
  • [5] CUDDY TE, 1987, PACE, V10, P435
  • [6] Dodinot B., 1985, Pacemaker Leads. Proceedings of the International Symposium, P75
  • [7] GASCON D, 1987, PACE, V10, P679
  • [8] HOFF PI, 1985, PACE, V8, pA4
  • [9] TRANSVENOUS ATRIAL-PACING FOLLOWING AMPUTATION OF THE ATRIAL APPENDAGE AT OPEN-HEART SURGERY
    KERR, CR
    MASON, MA
    TYERS, GFO
    BURR, LH
    JAMIESON, WRE
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1985, 8 (04): : 497 - 501
  • [10] A NEW GUIDEWIRE WITH KINK-RESISTANT CORE AND LOW-FRICTION COATING
    KIKUCHI, Y
    GRAVES, VB
    STROTHER, CM
    MCDERMOTT, JC
    BABEL, SG
    CRUMMY, AB
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1989, 12 (02) : 107 - 109