SELECTIVE DETERMINATION OF COBALT IN A STRONGLY ACIDIC MEDIUM BY FLOW-INJECTION ANALYSIS

被引:6
作者
DEALCARAZ, EC [1 ]
ROJAS, FS [1 ]
PAVON, JMC [1 ]
机构
[1] UNIV MALAGA,FAC SCI & POLYTECH SCH,DEPT ANALYT CHEM,E-29071 MALAGA,SPAIN
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1991年 / 340卷 / 03期
关键词
D O I
10.1007/BF00324477
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A selective method for the FIA spectrophotometric determination of Co(II) based on the use of pyridoxal 4-phenylthiosemicarbazone as reagent was developed with the aid of a straightforward 4-line flow injection manifold. The physical variables involved in the process were optimized as follows: injected sample volume 260-mu-l; reactor lengths 116 and 150 cm. The proposed method allows the determination of cobalt over the concentration range 0.4-14.4-mu-g ml-1 at a sampling rate of 48 samples h-1. The method is subject to very few interferences thanks to the fact that the strongly acidic medium used prevents the formation of most of the complexes of the reagent with other ions. It was applied to the determination of cobalt in steels.
引用
收藏
页码:175 / 177
页数:3
相关论文
共 15 条
[1]  
ALCARAZ EC, 1991, IN PRESS TALANTA
[2]   THE APPLICATION OF PH GRADIENTS IN FLOW-INJECTION ANALYSIS - A METHOD FOR SIMULTANEOUS DETERMINATION OF BINARY-MIXTURES OF METAL-IONS IN SOLUTION [J].
BETTERIDGE, D ;
FIELDS, B .
ANALYTICA CHIMICA ACTA, 1981, 132 (DEC) :139-155
[3]   FLOW-INJECTION ANALYSIS FOR MONITORING CHEMI-LUMINESCENT REACTIONS [J].
BURGUERA, JL ;
TOWNSHEND, A ;
GREENFIELD, S .
ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) :209-214
[4]   FLOW-INJECTION ANALYSIS OF COBALT(II) BY CATALYTIC OXIDATIONS OF STILBAZO AND PYROCATECHOL VIOLET [J].
DEGUCHI, T ;
HIGASHI, A ;
SANEMASA, I .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1986, 59 (01) :295-300
[5]   COMPARISON OF FLOW-INJECTION ANALYSIS CONFIGURATIONS FOR DIFFERENTIAL KINETIC DETERMINATION OF COBALT AND NICKEL [J].
FERNANDEZ, A ;
DECASTRO, MDL ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1984, 56 (07) :1146-1151
[6]  
FERNANDEZ A, 1987, QUIM ANAL, V6, P464
[7]   ANALYTICAL USE OF LUMINESCENCE INDUCED ULTRASONICALLY IN SOLUTION .1. SONIC CHEMILUMINESCENCE OF LUMINOL FOR DETERMINATION OF COBALT(II) AT SUB-PG LEVELS BY FLOW-INJECTION AND CONTINUOUS-FLOW METHODS [J].
KOMATSU, T ;
OHIRA, M ;
YAMADA, M ;
SUZUKI, S .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1986, 59 (06) :1849-1855
[8]  
MAEKOYA C, 1983, NIPPON KAGAKU KAISHI, V7, P1023
[9]   CHEMI-LUMINESCENCE FOR THE DETERMINATION OF TRACES OF COBALT(II) BY CONTINUOUS-FLOW AND FLOW-INJECTION METHODS [J].
NAKAHARA, S ;
YAMADA, M ;
SUZUKI, S .
ANALYTICA CHIMICA ACTA, 1982, 141 (SEP) :255-262
[10]  
Ruzicka J., 1981, FLOW INJECTION ANAL