CAN THE SAME EDGE-DETECTION ALGORITHM BE APPLIED TO ONLINE AND OFF-LINE ANALYSIS SYSTEMS - VALIDATION OF A NEW CINEFILM-BASED GEOMETRIC CORONARY MEASUREMENT SOFTWARE

被引:19
作者
HAASE, J [1 ]
VANDERLINDEN, MMJM [1 ]
DIMARIO, C [1 ]
VANDERGIESSEN, WJ [1 ]
FOLEY, DP [1 ]
SERRUYS, PW [1 ]
机构
[1] ERASMUS UNIV ROTTERDAM,CTR THORAX,CATHETERIZAT LAB,POB 1738,3000 DR ROTTERDAM,NETHERLANDS
关键词
D O I
10.1016/0002-8703(93)91045-G
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In the Cardiovascular Measurement System (CMS) the edge-detection algorithm, which was primarily designed for the Philips digital cardiac imaging system (DCI), is applied to cinefilms. Comparative validation of CMS and DCI was performed in vitro and in vivo with intracoronary insertion of stenosis phantoms in anesthetized pigs. The ''obstruction diameter'' (OD) was measured at the artificial stenoses visualized by angiography with calibration at the isocenter (ISO) and catheter calibration (CATH) and compared with the true phantom diameters. A clinical comparison of OD, reference diameter (RD), and percentage diameter stenosis (DS) was performed on 70 corresponding images from post-PTCA angiograms. In vitro, OD (CMS) yielded an accuracy of 0.18 +/- 0.14 mm with 100% (correlation coefficient: r = 0.97,y = 0.06 + 0.75x, standard error of estimate [SEE] = 0.09) and 0.19 +/- 0.15 mm with 50% contrast (r = 0.94,y = 0.02 + 0.81x). OD (DCI) yielded an accuracy of 0.11 +/- 0.06 mm with 100% (r = 0.99,y = - 0.03 + 0.91 x, SEE = 0.05) and 0.24 +/- 0.13 mm with 50% contrast (r = 0.94,y = 0.29 + 6.69x, SEE = 0.12). In vivo, OD (CMS) yielded an accuracy of 0.18 +/- 0.23 mm with ISO (r = 0.89,y = 0.02 + 0.83x, SEE = 0.22) and 0.26 +/- 0.24 mm with CATH (r = 0.89, y = 0.06 + 0.72x, SEE = 0.19). OD (DCI) yielded an accuracy of 0.08 +/- 0.15 mm with ISO (r = 0.96,y = 0.08 + 0.86x, SEE = 0.14) and 0.18 +/- 0.21 mm with CATH (r = 0.92,y = 0.09 + 0.76x, SEE = 0.17). The clinical comparison showed reasonable agreement for OD only (r = 0.81,y = 0.26 + 0.81x, SEE = 0.29). Transformation of an edge-detection algorithm from a digital to a cinefilm-based system can lead to impairment of measurement reliability.
引用
收藏
页码:312 / 321
页数:10
相关论文
共 22 条
  • [1] CHANGE IN DIAMETER OF CORONARY-ARTERY SEGMENTS ADJACENT TO STENOSIS AFTER PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY - FAILURE OF PERCENT DIAMETER STENOSIS MEASUREMENT TO REFLECT MORPHOLOGIC CHANGES INDUCED BY BALLOON DILATION
    BEATT, KJ
    LUIJTEN, HE
    DEFEYTER, PJ
    VANDENBRAND, M
    REIBER, JHC
    SERRUYS, PW
    TENKATEN, HJ
    VANES, GA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 12 (02) : 315 - 323
  • [2] RESTENOSIS AFTER CORONARY ANGIOPLASTY - NEW STANDARDS FOR CLINICAL-STUDIES
    BEATT, KJ
    SERRUYS, PW
    HUGENHOLTZ, PG
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 15 (02) : 491 - 498
  • [3] BLAND JM, 1986, LANCET, V2, P397
  • [4] CORONARY ANGIOGRAPHIC EXAMINATION WITH THE DYNAMIC SPATIAL RECONSTRUCTOR
    BLOCK, M
    BOVE, AA
    RITMAN, EL
    [J]. CIRCULATION, 1984, 70 (02) : 209 - 216
  • [5] QUANTITATIVE CORONARY ANGIOGRAPHY TO MEASURE PROGRESSION AND REGRESSION OF CORONARY ATHEROSCLEROSIS - VALUE, LIMITATIONS, AND IMPLICATIONS FOR CLINICAL-TRIALS
    DEFEYTER, PJ
    SERRUYS, PW
    DAVIES, MJ
    RICHARDSON, P
    LUBSEN, J
    OLIVER, MF
    [J]. CIRCULATION, 1991, 84 (01) : 412 - 423
  • [6] PITFALLS IN THE DETERMINATION OF ABSOLUTE DIMENSIONS USING ANGIOGRAPHIC CATHETERS AS CALIBRATION DEVICES IN QUANTITATIVE ANGIOGRAPHY
    FORTIN, DF
    SPERO, LA
    CUSMA, JT
    SANTORO, L
    BURGESS, R
    BASHORE, TM
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (11) : 1176 - 1182
  • [7] GOULD KL, 1991, CORONARY ARTERY STEN, P93
  • [8] INVIVO VALIDATION OF ONLINE AND OFF-LINE GEOMETRIC CORONARY MEASUREMENTS USING INSERTION OF STENOSIS PHANTOMS IN PORCINE CORONARY-ARTERIES
    HAASE, J
    DIMARIO, C
    SLAGER, CJ
    VANDERGIESSEN, WJ
    DENBOER, A
    DEFEYTER, PJ
    REIBER, JHC
    VERDOUW, PD
    SERRUYS, PW
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1992, 27 (01): : 16 - 27
  • [9] DIGITAL GEOMETRIC MEASUREMENTS IN COMPARISON TO CINEFILM ANALYSIS OF CORONARY-ARTERY DIMENSIONS
    HAASE, J
    NUGTEREN, SK
    VANSWIJNDREGT, EM
    SLAGER, CJ
    DIMARIO, C
    DEFEYTER, PJ
    SERRUYS, PW
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 28 (04): : 283 - 290
  • [10] KONING G, 1991, 4TH INT S COR ART RO, P168