Bridges to establish an emergency airway and alternate intubating techniques

被引:10
作者
Foley, LJ [1 ]
Ochroch, EA [1 ]
机构
[1] Winchester Hosp, Dept Anesthesia, Winchester, MA 01890 USA
关键词
D O I
10.1016/S0749-0704(05)70121-4
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
In this article, a number of alternatives to direct laryngoscopy are examined. These alternatives include the laryngeal mask airway (LMA; LMA North America, San Diego, CA), cuffed oropharyngeal airway (COPA; Mallinckrodt, St. Louis, MO), and Combitube (Kendall-Sheridan, Mansfield, MA), that have been designed to act as bridges to establish an airway. Other devices, such as rigid stylets, the lightwand (a blind technique) and indirect fiberoptic rigid stylets, such as the Bullard scope, Upsher scope, and Wu scope are also briefly discussed.
引用
收藏
页码:429 / +
页数:17
相关论文
共 57 条
[1]   A COMPARISON OF THE LARYNGEAL MASK AIRWAY AND GUEDEL AIRWAY, BAG AND FACEMASK FOR MANUAL VENTILATION FOLLOWING FORMAL TRAINING [J].
ALEXANDER, R ;
HODGSON, P ;
LOMAX, D ;
BULLEN, C .
ANAESTHESIA, 1993, 48 (03) :231-234
[2]   CRICOID PRESSURE MAY PREVENT INSERTION OF THE LARYNGEAL MASK AIRWAY [J].
ANSERMINO, JM ;
BLOGG, CE .
BRITISH JOURNAL OF ANAESTHESIA, 1992, 69 (05) :465-467
[3]   Cricoid pressure impedes positioning and ventilation through the laryngeal mask airway [J].
Aoyama, K ;
Takenaka, I ;
Sata, T ;
Shigematsu, A .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1996, 43 (10) :1035-1040
[4]   Cricoid pressure applied after placement of the laryngeal mask prevents gastric insufflation but inhibits ventilation [J].
Asai, T ;
Barclay, K ;
McBeth, C ;
Vaughan, RS .
BRITISH JOURNAL OF ANAESTHESIA, 1996, 76 (06) :772-776
[5]   CRICOID PRESSURE AND THE LMA - EFFICACY AND INTERPRETATION - REPLY [J].
ASAI, T ;
BARCLAY, K ;
POWER, I ;
VAUGHAN, RS .
BRITISH JOURNAL OF ANAESTHESIA, 1994, 73 (06) :863-865
[6]   Appropriate size and inflation of the laryngeal mask airway [J].
Asai, T ;
Howell, TK ;
Koga, K ;
Morris, S .
BRITISH JOURNAL OF ANAESTHESIA, 1998, 80 (04) :470-474
[7]   SINGLE-HANDED COMPARED WITH DOUBLE-HANDED CRICOID PRESSURE FOR INSERTION OF AN LMA - REPLY [J].
ASAI, T ;
BARCLAY, K ;
POWER, I ;
VAUGHAN, RS .
BRITISH JOURNAL OF ANAESTHESIA, 1994, 72 (06) :733-734
[8]   Laryngeal mask airway and the ASA difficult airway algorithm [J].
Benumof, JL .
ANESTHESIOLOGY, 1996, 84 (03) :686-699
[9]   THE LARYNGEAL MASK - A NEW CONCEPT IN AIRWAY MANAGEMENT [J].
BRAIN, AIJ .
BRITISH JOURNAL OF ANAESTHESIA, 1983, 55 (08) :801-805
[10]   CRICOID PRESSURE AND THE LMA - EFFICACY AND INTERPRETATION [J].
BRIMACOMBE, J ;
BERRY, A .
BRITISH JOURNAL OF ANAESTHESIA, 1994, 73 (06) :862-863