MINIMIZING RADIATION-DOSE TO PATIENT AND STAFF DURING FLUOROSCOPIC, NASOENTERAL TUBE INSERTIONS

被引:9
作者
RUDIN, S
BEDNAREK, DR
机构
[1] Department of Radiology, State Uni New York at Buffalo, School of Medicine, Buffalo, NY 14215
关键词
RADIATION DOSE REDUCTION; FLUOROSCOPY; NASOENTERAL TUBE INSERTION;
D O I
10.1259/0007-1285-65-770-162
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
It is possible to reduce greatly fluoroscopic radiation dose if some image degradation is acceptable. Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate that were investigated consisted of removing the antiscatter grid, increasing the diameter of the optical aperture controlling the percentage of light reaching the television camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure.
引用
收藏
页码:162 / 166
页数:5
相关论文
共 21 条
[1]  
ABBOTT WC, 1987, SURG GYNECOL OBSTET, V157, P585
[2]   BENEFICIAL-EFFECTS OF AGGRESSIVE PROTEIN FEEDING IN SEVERELY BURNED CHILDREN [J].
ALEXANDER, JW ;
MACMILLAN, BG ;
STINNETT, JD ;
OGLE, C ;
BOZIAN, RC ;
FISCHER, JE ;
OAKES, JB ;
MORRIS, MJ ;
KRUMMEL, R .
ANNALS OF SURGERY, 1980, 192 (04) :505-517
[3]   ASSESSMENT OF PATIENT EXPOSURE FOR BARIUM ENEMA EXAMINATIONS [J].
BEDNAREK, DR ;
RUDIN, S ;
WONG, R .
INVESTIGATIVE RADIOLOGY, 1983, 18 (05) :453-458
[4]   REDUCTION OF FLUOROSCOPIC EXPOSURE FOR THE AIR-CONTRAST BARIUM ENEMA [J].
BEDNAREK, DR ;
RUDIN, S ;
WONG, R ;
ANDRES, ML .
BRITISH JOURNAL OF RADIOLOGY, 1983, 56 (671) :823-828
[5]   THE GUT ORIGIN SEPTIC STATES IN BLUNT MULTIPLE TRAUMA (ISS = 40) IN THE ICU [J].
BORDER, JR ;
HASSETT, J ;
LADUCA, J ;
SEIBEL, R ;
STEINBERG, S ;
MILLS, B ;
LOSI, P ;
BORDER, D .
ANNALS OF SURGERY, 1987, 206 (04) :427-448
[6]  
BOUCEK RJ, 1984, OTOLARYNG CLIN N AM, V17, P243
[7]  
CEMBER H, 1969, INTRO HLTH PHYSICS, P280
[8]   AN ASSESSMENT OF THE RADIATION-DOSE RECEIVED BY STAFF USING FLUOROSCOPIC EQUIPMENT [J].
FAULKNER, K ;
MOORES, BM .
BRITISH JOURNAL OF RADIOLOGY, 1982, 55 (652) :272-276
[9]   RAPID FLUOROSCOPIC DUODENAL INTUBATION [J].
GIANTURCO, C .
RADIOLOGY, 1967, 88 (06) :1165-+
[10]   THE ELIMINATION OF GRIDS DURING INTENSIFIED FLUOROSCOPY AND PHOTOFLUORO SPOT IMAGING [J].
GRAY, JE ;
SWEE, RG .
RADIOLOGY, 1982, 144 (02) :426-429