CENTRAL VENOUS VERSUS MIXED VENOUS OXYGEN-CONTENT

被引:19
作者
FABER, T [1 ]
机构
[1] BISPEBJERG UNIV HOSP,DEPT ANAESTHESIOL & INTENS CARE,DK-2400 COPENHAGEN NV,DENMARK
关键词
BLOOD CARBON DIOXIDE CONTENT; CENTRAL VENOUS OXYGEN CONTENT; MIXED VENOUS OXYGEN CONTENT; OXYGEN TRANSPORT MONITORING;
D O I
10.1111/j.1399-6576.1995.tb04327.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Mixed venous oxygen content (commonly measured as oxygen saturation) is a highly relevant parameter in the monitoring of critically ill patients; unfortunately, its measurement requires catheterization of the pulmonary artery. Though less invasive, the central venous oxygen saturation is an unsatisfactory substitute, due to fluctuations in perfusion distribution and regional oxygen extraction in the course of illness. The present study examined the relation of oxygen contents in simultaneously withdrawn central venous and mixed venous blood samples from critically ill patients, in order to validate a hypothetical algorithm for the estimation of mixed venous oxygen content from a central venous sample: Although the proposed algorithm had a fairly high power of prediction, its merits in comparison to assuming simple proportionality between central venous and mixed venous oxygen content seemed marginal. However, as it is likely that the results so far are mathematically coupled, further prospective studies are necessary.
引用
收藏
页码:33 / 36
页数:4
相关论文
共 6 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
MARTIN C, 1992, INTENS CARE MED, V8, P101
[3]  
SCHEINMAN MM, 1969, CIRCULATION, V15, P165
[4]  
SIGGAARDANDERSE.O, 1988, SCAND J CLIN LA S189, V48, P7
[5]  
Tatman D J, 1990, Can J Anaesth, V37, pS154
[6]  
Wendt M, 1990, Anasth Intensivther Notfallmed, V25, P102, DOI 10.1055/s-2007-1001030