IONIC-STRENGTH AND CHARGE NUMBER CORRECTION FOR MOBILITIES OF MULTIVALENT ORGANIC-ANIONS IN CAPILLARY ELECTROPHORESIS

被引:133
作者
FRIEDL, W
REIJENGA, JC
KENNDLER, E
机构
[1] EINDHOVEN UNIV TECHNOL,DEPT CHEM ENGN,5600 MB EINDHOVEN,NETHERLANDS
[2] UNIV VIENNA,INST ANALYT CHEM,A-1090 VIENNA,AUSTRIA
关键词
D O I
10.1016/0021-9673(95)00159-K
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An empirical expression was derived for the actual mobility, mu, valid in an extended range of ionic strength, I, between 0.001 and 0.1 mol/l, using a three-parameter exponential fit for the ratio of actual and absolute mobilities (mu(0) at I = 0), which consists of two variables: ionic strength of the buffer and charge number, z, of the solute. The charge numbers of the solute anions (21 aromatic sulfonates) ranged between 1 and 6, and the ionic strength was varied in the range mentioned using a sodium acetate buffer. The mobilities were determined at 25.0 degrees C in a coated capillary with suppressed electroosmotic flow. The resulting fitting equation, valid under these conditions, is mu/mu(0) = exp(-0.77 root zI). The difference between measured mobilities and mobilities calculated from a tenfold higher or lower ionic strength, using this equation, is within 5% for all experiments. For multivalent ions, mu values can be derived from mu(0) with comparable accuracy.
引用
收藏
页码:163 / 170
页数:8
相关论文
共 16 条
[1]   CAPILLARY ZONE ELECTROPHORETIC SEPARATIONS OF PROTEINS IN POLYETHYLENE GLYCOL-MODIFIED CAPILLARIES [J].
BRUIN, GJM ;
CHANG, JP ;
KUHLMAN, RH ;
ZEGERS, K ;
KRAAK, JC ;
POPPE, H .
JOURNAL OF CHROMATOGRAPHY, 1989, 471 :429-436
[2]  
Deml M., 1988, ANAL ISOTACHOPHORESI
[3]  
Everaerts FM, 1976, J CHROMATOGRAPHY LIB, V6
[4]  
FORET F, 1989, ADV ELECTROPHORESIS, V3, P273
[5]   RESOLUTION AS A FUNCTION OF THE PH OF THE BUFFER BASED ON THE ANALYTE CHARGE NUMBER FOR MULTIVALENT IONS IN CAPILLARY ZONE ELECTROPHORESIS WITHOUT ELECTROOSMOTIC FLOW - THEORETICAL PREDICTION AND EXPERIMENTAL EVALUATION [J].
FRIEDL, W ;
KENNDLER, E .
ANALYTICAL CHEMISTRY, 1993, 65 (15) :2003-2009
[6]   EFFECT OF THE NUMBER OF SULFO GROUPS ON THE ELECTROPHORETIC MOBILITY OF SULFONATED AZO DYES [J].
GASPARIC, J ;
SEDMIKOVA, A .
JOURNAL OF CHROMATOGRAPHY A, 1994, 665 (01) :197-202
[7]   HIGH-SPEED ELECTROPHORESIS SIMULATION FOR OPTIMIZATION OF CONTINUOUS-FLOW ELECTROPHORESIS AND HIGH-PERFORMANCE CAPILLARY TECHNIQUES .1. COMPUTER-MODEL [J].
HEINRICH, J ;
WAGNER, H .
ELECTROPHORESIS, 1992, 13 (1-2) :44-49
[8]  
Hjerten S, 1967, Chromatogr Rev, V9, P122, DOI 10.1016/0009-5907(67)80003-6
[9]   THE EFFECT OF ELECTRIC-FIELD STRENGTH, BUFFER TYPE AND CONCENTRATION ON SEPARATION PARAMETERS IN CAPILLARY ZONE ELECTROPHORESIS [J].
ISSAQ, HJ ;
ATAMNA, IZ ;
MUSCHIK, GM ;
JANINI, GM .
CHROMATOGRAPHIA, 1991, 32 (3-4) :155-161
[10]  
KENNEDLER E, 1991, J CHROMATOGR, V608, P161