VOLUME MR ANGIOGRAPHY - METHODS TO ACHIEVE VERY SHORT ECHO TIMES

被引:108
作者
SCHMALBROCK, P
YUAN, C
CHAKERES, DW
KOHLI, J
PELC, NJ
机构
[1] GE MED SYST,MILWAUKEE,WI
[2] DEPT RADIOL,DIV NEURORADIOL,COLUMBUS,OH
关键词
cerebral blood vessels; MR studies; magnetic resonance (MR); pulse sequences; rapid imaging;
D O I
10.1148/radiology.175.3.2343137
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Angiographic displays of cerebral vessels can be generated with single-excitation three-dimensional magnetic resonance imaging. Differentiation of true stenosis from artifactual signal loss, due to dephasing effects from fast or nonconstant blood flow and field inhomogeneities, poses a significant clinical problem that can be largely resolved with the use of very short echo times (TEs). A three-dimensional imaging technique was developed that allows TEs of 3.1 msec without and 4.5 msec with first-order flow compensation gradients. The short TEs were achieved with short asymmetric radio-frequency pulses, gradients of minimal duration, and fractional echoes. Significantly improved images of normal tortuous vessels with fast flow were obtained. With this method, accuracy in depicting the vessel lumen and confidence in the findings were markedly increased.
引用
收藏
页码:861 / 865
页数:5
相关论文
共 13 条
  • [1] CHAKERES DW, IN PRESS AJNR
  • [2] 3-DIMENSIONAL PHASE-CONTRAST ANGIOGRAPHY
    DUMOULIN, CL
    SOUZA, SP
    WALKER, MF
    WAGLE, W
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (01) : 139 - 149
  • [3] 3-DIMENSIONAL TIME-OF-FLIGHT MAGNETIC-RESONANCE ANGIOGRAPHY USING SPIN SATURATION
    DUMOULIN, CL
    CLINE, HE
    SOUZA, SP
    WAGLE, WA
    WALKER, MF
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1989, 11 (01) : 35 - 46
  • [4] THE EFFECTS OF FINITE SAMPLING IN SPIN-ECHO OR FIELD-ECHO MAGNETIC-RESONANCE-IMAGING
    HAACKE, EM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (05) : 407 - 421
  • [5] MR ANGIOGRAPHY WITH TWO-DIMENSIONAL ACQUISITION AND 3-DIMENSIONAL DISPLAY - WORK IN PROGRESS
    KELLER, PJ
    DRAYER, BP
    FRAM, EK
    WILLIAMS, KD
    DUMOULIN, CL
    SOUZA, SP
    [J]. RADIOLOGY, 1989, 173 (02) : 527 - 532
  • [6] KERBER CW, 1989, 27TH ANN M AM SOC NE
  • [7] MR ANGIOGRAPHY WITH GRADIENT MOTION REFOCUSING
    LAUB, GA
    KAISER, WA
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (03) : 377 - 382
  • [8] MACOVSKI A, 1988, SOC MAGNETIC RESONAN, V2, P815
  • [9] MAGNETIC-RESONANCE ANGIOGRAPHY BY SELECTIVE INVERSION RECOVERY USING A COMPACT GRADIENT ECHO SEQUENCE
    NISHIMURA, DG
    MACOVSKI, A
    JACKSON, JI
    HU, RS
    STEVICK, CA
    AXEL, L
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1988, 8 (01) : 96 - 103
  • [10] PROVST TJ, 1986, SOC MAGNETIC RESONAN, V1, P265