SEMIPREPARATIVE PURIFICATION OF AN ENDOGENOUS LIGAND FOR BRAIN SEROTONIN-2 RECEPTORS BY COIL PLANET CENTRIFUGE COUNTERCURRENT CHROMATOGRAPHY

被引:10
作者
APUD, JA [1 ]
ITO, Y [1 ]
机构
[1] NHLBI,BIOPHYS CHEM LAB,BLDG 10,ROOM 7N-322,BETHESDA,MD 20892
来源
JOURNAL OF CHROMATOGRAPHY | 1991年 / 538卷 / 01期
关键词
D O I
10.1016/S0021-9673(01)91635-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A horizontal flow-through coil planet centrifuge equipped with a rotatory frame holding three sets of composite column assemblies was used for purification of an endogenous ligand (ketanserin binding inhibitor) for the [H-3]-ketanserin (H-3-KET) recognition site. The protein mixture containing the endogenous material was successfully resolved by using a two-phase solvent system consisting of 95% ethanol-31.5% ammonium sulphate (1:2). The active fractions on H-3-KET binding obtained after counter-current chromatography (CCC) were further purified through a C18-mu-Bondapak reversed-phase high-pressure liquid chromatographic column. The introduction of this advanced CCC technique represents an important step in the application of CCC for the separation of polar proteins from protein mixtures.
引用
收藏
页码:177 / 185
页数:9
相关论文
共 12 条
[1]  
Albertsson P. A., 1986, PARTITION CELL PARTI
[2]   DIFFERENCES IN THE REGULATORY ADAPTATION OF THE 5HT2 RECOGNITION SITES LABELED BY H-3-LABELED MIANSERIN OR H-3-LABELED KETANSERIN [J].
BARBACCIA, ML ;
GANDOLFI, O ;
CHUANG, DM ;
COSTA, E .
NEUROPHARMACOLOGY, 1983, 22 (01) :123-126
[3]   EVALUATION OF NONAQUEOUS SOLVENT SYSTEMS FOR COUNTERCURRENT CHROMATOGRAPHY USING AN HPLC ASSAY TO DETERMINE PARTITION-COEFFICIENTS OF A MIXTURE OF COMPOUNDS [J].
CONWAY, WD ;
ITO, Y .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1984, 7 (02) :291-302
[4]  
DEUTSCHER MP, 1990, METHOD ENZYMOL, V182, P309
[5]   DIFFERENT EFFECTS OF SEROTONIN ANTAGONISTS ON H-3 MIANSERIN AND H-3 KETANSERIN RECOGNITION SITES [J].
GANDOLFI, O ;
BARBACCIA, ML ;
COSTA, E .
LIFE SCIENCES, 1985, 36 (08) :713-721
[6]  
HANBAUER I, IN PRESS J LIQ CHROM
[7]   HIGH-SPEED COUNTERCURRENT CHROMATOGRAPHY [J].
ITO, Y .
CRC CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1986, 17 (01) :65-143
[8]   EXPERIMENTAL-OBSERVATIONS OF THE HYDRODYNAMIC BEHAVIOR OF SOLVENT SYSTEMS IN HIGH-SPEED COUNTERCURRENT CHROMATOGRAPHY .3. EFFECTS OF PHYSICAL-PROPERTIES OF THE SOLVENT SYSTEMS AND OPERATING TEMPERATURE ON THE DISTRIBUTION OF 2-PHASE SOLVENT SYSTEMS [J].
ITO, Y ;
CONWAY, WD .
JOURNAL OF CHROMATOGRAPHY, 1984, 301 (02) :405-414
[9]  
LEYSEN JE, 1982, MOL PHARMACOL, V21, P301
[10]  
MANDAVA NB, 1988, COUNTERCURRENT CHROM